Possibility of increasing linear energy transfer in multi‐ion radiotherapy for bone and soft tissue sarcomas

Hideyuki Takei, Reiko Imai, Takamitsu Masuda, Katsumi Aoki, Taku Nakaji, Yusuke Nomura, Asami Inomata, Yui Suzuki, Taku Inaniwa

Medical Physics · 2025

DOI: 10.1002/mp.18097 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Medical Physics, 2025. Verfasst von Hideyuki Takei und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Accelerator and Medical Physics, National Institutes for Quantum Science and Technology (QST), Chiba, Japan. Hauptthemen laut MEDLINE: Heavy Ion Radiotherapy, Sarcoma, Linear Energy Transfer, Bone Neoplasms. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 37 Literaturangaben. Gefördert von: JSPS, Japan Society for the Promotion of Science.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Multi‐ion radiotherapy using carbon, oxygen, and neon ions aims to improve local control by increasing dose‐averaged linear energy transfer (LET d ) in the target. However, there has been limited understanding of how to utilize variables for multi‐ion treatment planning such as the selection and arrangement of ion species.

Purpose

An in silico study was conducted to explore the feasibility of increasing a minimum LET d , and the optimal selection and arrangement of ion species in multi‐ion therapy for increasing LET d in tumors of varying sizes mimicking bone and soft tissue sarcomas (BSTS). Additionally, the robustness of multi‐ion therapy against setup and range errors was evaluated.

Methods

Spherical targets of 500, 1000, and 1500‐mL volumes were placed at the center or 80 mm horizontally displaced from the center of a numerical phantom to simulate BSTS treatments. Treatment plans were made for these targets with two orthogonal fields of carbon‐only, oxygen+carbon, and neon+carbon ions with a total dose of 70.4 Gy (RBE). The treatment parameters were optimized to increase the LET d in the targets while ensuring adequate target dose coverage and dose homogeneity. The plans were evaluated based on the dose covering 95% of the target ( D 95% ), skin dose ( D skin ), and the minimum LET d excluding the 1 mL volume with the lowest LET d ( L 1mL ). Multi‐ion radiotherapy treatment plans were also developed for 12 patients with BSTS who had previously received carbon‐ion radiotherapy. D 95% and L 1m of the target, and the dose to organs at risk (OARs) such as the rectum, intestine, and spinal cord were assessed. The robustness of the plans created in the phantom against setup and range errors was evaluated under 2 mm shifts in six directions combined with 2.5% variation of the stopping power ratio, resulting in 12 scenarios. Differences in the target D 95% and L 1mL , and D skin in each scenario from those in the nominal plan were evaluated.

Results

The target dose coverage was comparable for any ion species combinations regardless of target size and position. The L 1mL in the target increased by 7–9 and 15–20 keV/µm with the oxygen+carbon and neon+carbon plans, respectively, compared to the carbon‐only plans, while maintaining homogeneity index values below 0.10. Additionally, the skin dose increased by 2.2–7.0 and 9.2–14.6 Gy (RBE) for the oxygen+carbon and neon+carbon plans. The L 1mL was greater than or equal to 40 keV/µm in all phantom targets and most clinical cases for the oxygen+carbon and neon+carbon plans, while meeting the target and OAR dose requirements. In the robustness evaluation, the variations in D 95% were comparable or smaller in the oxygen+carbon and neon+carbon plans than in the carbon‐only plan. The maximum decrease in L 1mL in the target was 1.5 keV/µm. The maximum increase in D skin was 2.4 Gy (RBE) in the target closest to the skin.

Conclusions

The LET d was successfully increased with the oxygen+carbon and neon+carbon ions, while meeting the dose requirements. The multi‐ion therapy plans created using the method presented in this study were robust to setup and range errors.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Heavy Ion RadiotherapySarcomaLinear Energy TransferBone NeoplasmsSoft Tissue NeoplasmsHumansRadiotherapy Planning, Computer-AssistedRadiotherapy DosagePhantoms, Imaging

Stichwörter der Autor:innen

heavy ion therapymulti‐ion therapytreatment planning

Autor:innen und Institutionen

  • Department of Accelerator and Medical Physics, National Institutes for Quantum Science and Technology (QST), Chiba, Japan.
  • QST Hospital, National Institutes for Quantum Science and Technology (QST), Chiba, Japan.
  • Treatment Planning Group, Accelerator Engineering Corporation, Chiba, Japan.

Förderung

  • JSPS
  • Japan Society for the Promotion of Science

Zitieren

APA

Takei, H., Imai, R., Masuda, T., Aoki, K., Nakaji, T., Nomura, Y., Inomata, A., Suzuki, Y., & Inaniwa, T. (2025). Possibility of increasing linear energy transfer in multi‐ion radiotherapy for bone and soft tissue sarcomas. Medical Physics. https://doi.org/10.1002/mp.18097

Vancouver

Takei H, Imai R, Masuda T, Aoki K, Nakaji T, Nomura Y, et al. Possibility of increasing linear energy transfer in multi‐ion radiotherapy for bone and soft tissue sarcomas. Medical Physics. 2025. doi:10.1002/mp.18097

BibTeX
@article{Takei2025,
  author = {Takei, Hideyuki and Imai, Reiko and Masuda, Takamitsu and Aoki, Katsumi and Nakaji, Taku and Nomura, Yusuke and Inomata, Asami and Suzuki, Yui and Inaniwa, Taku},
  title = {Possibility of increasing linear energy transfer in multi‐ion radiotherapy for bone and soft tissue sarcomas},
  journal = {Medical Physics},
  year = {2025},
  doi = {10.1002/mp.18097}
}
Infokarte | EUVIMED

Artikeldaten derzeit nicht verfügbar.

Recherche