EUVIMEDAtrasti EUVIMED
Open access

AI-Enabled Wearable Ultrasound for Noninvasive Central Venous Pressure Monitoring

Liping Dong, Xingxuan Zhang, Meng Li, Yi Li, Jingyi Guo, Shaorong Lu, Zhenyu Peng, Chenxi Zheng, Yufei Hui, Xiaoping Shao, Feiyan Wang, Weikang Jiang and 6 more

Cyborg and Bionic Systems · 2026-01-01 · 7

DOI: 10.34133/cbsystems.0653 ↗

At a glance

Journal article in Cyborg and Bionic Systems, published online on 2026-08-05. Written by Liping Dong and 17 co-authors. Institution: Department of Ultrasound, Shanghai Sixth People's Hospital Affiliated to Shanghai Jiao Tong University School of Medicine; Shanghai Institute of Ultr…. Cited 3 times so far (Crossref); 41 references. The full text is freely available in PubMed Central. Funded by: Shanghai Municipal Health Commission, Shanghai sixth people Hospital Affiliated with Shanghai Jiao Tong University.

SantraukaBibliografiniai duomenysCiteRelated studies

Abstract (original language)

Central venous pressure (CVP) is a key indicator of right ventricular preload, but measurement with a central venous catheter (CVC) is invasive, time-consuming, and unsuitable for bedside monitoring. We developed and clinically evaluated an artificial intelligence (AI)-enabled wearable ultrasound device for noninvasive estimation of elevated CVP by imaging the internal jugular vein (IJV) and common carotid artery (CCA) in acute and critical patients. In this prospective multi-center clinical study, 349 patients admitted to intensive care units (ICUs) at 2 tertiary hospitals underwent neck vascular imaging with the wearable ultrasound device, while CVP was measured simultaneously via CVC as the reference standard. The dual-decoder spatiotemporal attention network (DSTA-Net) segmentation model automatically quantified IJV and CCA cross-sectional areas, and the dual-modality multilayer perceptron (DM-MLP) integrated these vascular indices with basic clinical parameters to predict elevated CVP (≥8 mmHg). DSTA-Net showed excellent agreement and strong correlation with expert manual measurements while achieving superior segmentation accuracy compared with the baseline segmentation model. Meanwhile, the proposed DM-MLP improved prediction performance by 4% to 8% over conventional baseline architectures, achieving AUCs of 0.91 (internal test set) and 0.87 (external test set). These findings indicate that an AI-integrated wearable ultrasound device can provide accurate, noninvasive bedside assessment of CVP and may offer a promising alternative to invasive catheters for hemodynamic monitoring in acute and critical care settings.

Authors and institutions

  • Department of Ultrasound, Shanghai Sixth People's Hospital Affiliated to Shanghai Jiao Tong University School of Medicine; Shanghai Institute of Ultrasound in Medicine, Shanghai 200233, China.
  • Shanghai Key Laboratory of Neuro-Ultrasound for Diagnosis and Treatment, Shanghai 200233, China.
  • Department of Clinical Research Center, Shanghai Sixth People's Hospital, Shanghai Jiao Tong University of Medicine, Shanghai 200233, China.
  • Department of Biomedical Science, King's College London, London SE1 9RT, UK.
  • Department of Chemistry, University of Illinois Urbana-Champaign, Champaign, IL 61801, USA.
  • Department of Emergency Medicine, Shanghai Sixth People's Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai 200233, China.

Funding

  • Shanghai Municipal Health Commission
  • Shanghai sixth people Hospital Affiliated with Shanghai Jiao Tong University

Cite

APA

Dong, L., Zhang, X., Li, M., Li, Y., Guo, J., Lu, S., Peng, Z., Zheng, C., Hui, Y., Shao, X., Wang, F., Jiang, W., Li, M., Wu, X., Guo, X., Li, Y., Zheng, Y., & Zhang, L. (2026). AI-Enabled Wearable Ultrasound for Noninvasive Central Venous Pressure Monitoring. Cyborg and Bionic Systems, 7. https://doi.org/10.34133/cbsystems.0653

Vancouver

Dong L, Zhang X, Li M, Li Y, Guo J, Lu S, et al. AI-Enabled Wearable Ultrasound for Noninvasive Central Venous Pressure Monitoring. Cyborg and Bionic Systems. 2026;7. doi:10.34133/cbsystems.0653

BibTeX
@article{Dong2026,
  author = {Dong, Liping and Zhang, Xingxuan and Li, Meng and Li, Yi and Guo, Jingyi and Lu, Shaorong and Peng, Zhenyu and Zheng, Chenxi and Hui, Yufei and Shao, Xiaoping and Wang, Feiyan and Jiang, Weikang and Li, Maoyao and Wu, Xianshuai and Guo, Xu and Li, Yingchuan and Zheng, Yuanyi and Zhang, Liping},
  title = {AI-Enabled Wearable Ultrasound for Noninvasive Central Venous Pressure Monitoring},
  journal = {Cyborg and Bionic Systems},
  year = {2026},
  volume = {7},
  doi = {10.34133/cbsystems.0653}
}
Start for free →