Noninvasive Blood Pressure Monitoring via a Flexible and Wearable Piezoresistive Sensor
ACS Omega · 13.02.2024 · 9 (6) · 6355-6365
DOI: 10.1021/acsomega.3c04786 ↗Kurz gefasst
Fachartikel in der Zeitschrift ACS Omega, online erschienen am 01.02.2024. Verfasst von Bijender und 5 weiteren Autor:innen. Beteiligte Einrichtung: CSIR-National Physical Laboratory, Dr. K. S. Krishnan Marg, New Delhi 110012, India. Die Arbeit wurde bisher 24-mal zitiert (Crossref) und nennt 76 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: National Physical Laboratory, Academy of Scientific and Innovative Research.
Abstract (Originalsprache)
In the present global context, continuous blood pressure (BP) monitoring is paramount in addressing the global mortality rates attributed to hypertension. Achieving precise insights into the human cardiovascular system necessitates accurate measurement of BP, and the accuracy depends on the faithful recording of oscillations or pulsations. This task ultimately depends on the caliber of the pressure sensor embedded in the BP device. In this context, we have fabricated a flexible resistive pressure sensor based on reduced graphene oxide (rGO) and a polydimethylsiloxane (PDMS) sponge that is highly flexible and sensitive. The designed device operates effectively with a minimal bias voltage of 500 mV, at which point it showed its maximum relative change in current, reaching approximately 25%. Additionally, the sensing device showed a notable change in resistance values, exhibiting almost 100% change in resistance when subjected to a pressure of 400 mmHg and high sensitivity of 0.27 mmHg–1. After promising outcomes were obtained during static pressure measurement, the sensor was used for BP monitoring in humans. The sensor accurately traced the oscillometric waveform (OMW) for distinct systolic blood pressure (SBP) and diastolic blood pressure (DBP) combinations to cover a range of medical situations, including hypotension, standard or normal, and hypertension. The values of SBP, DBP, and MAP were derived from the sensor’s output using the MAA technique, and the errors in these values concerning the simulator and the traditional BP monitor follow the universal AAMI/ESH/ISO protocols. Bland-Altman (B&A) correlation and scatter plots were used to compare the sensor’s results and further validate the proposed sensor. The sensor showed the mean and standard deviation error in the SBP, DBP, and MBP of −0.2 ± 5.9, −0.5 ± 7, and −0.9 ± 4.7 mmHg when compared with the noninvasive blood pressure (NIBP) simulator. The pulse rate (PR) was also calculated from the same OMW for the specified value of 80 beats per minute (bpm) given by the simulator and reported a mean PR value of ∼81 bpm, close to the reference value. The findings show that the flexible resistive sensing device can accurately measure BP and replace the existing sensors of BP devices.
Autor:innen und Institutionen
- CSIR-National Physical Laboratory, Dr. K. S. Krishnan Marg, New Delhi 110012, India.
- Academy of Scientific and Innovative Research (AcSIR), Ghaziabad 201002, India.
ORCID-Profile: Bijender, Shubham Kumar, Ashok Kumar
Förderung
- National Physical Laboratory
- Academy of Scientific and Innovative Research
Zitieren
APA
Bijender, Kumar, S., Soni, A., Yadav, R., Singh, S. P., & Kumar, A. (2024). Noninvasive Blood Pressure Monitoring via a Flexible and Wearable Piezoresistive Sensor. ACS Omega, 9(6), 6355-6365. https://doi.org/10.1021/acsomega.3c04786
Vancouver
Bijender, Kumar S, Soni A, Yadav R, Singh SP, Kumar A. Noninvasive Blood Pressure Monitoring via a Flexible and Wearable Piezoresistive Sensor. ACS Omega. 2024;9(6):6355-6365. doi:10.1021/acsomega.3c04786
BibTeX
@article{Bijender2024,
author = {Bijender and Kumar, Shubham and Soni, Amit and Yadav, Rimjhim and Singh, Surinder P and Kumar, Ashok},
title = {Noninvasive Blood Pressure Monitoring via a Flexible and Wearable Piezoresistive Sensor},
journal = {ACS Omega},
year = {2024},
volume = {9},
number = {6},
pages = {6355--6365},
doi = {10.1021/acsomega.3c04786}
}
EUVIMED