Kurz gefasst

Vergleichsstudie in der Zeitschrift Tomography, 2024. Verfasst von Anna Klempka und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Neuroradiology, University Medical Centre Mannheim, Medical Faculty Mannheim, University of Heidelberg, 68167 Mannheim, Germany. Hauptthemen laut MEDLINE: Phantoms, Imaging, Tomography, X-Ray Computed, Imaging, Three-Dimensional, Cerebrospinal Fluid Shunts. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 26 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This study introduces an application of innovative medical technology, Photon Counting Computer Tomography (PC CT) with novel detectors, for the assessment of shunt valves. PC CT technology offers enhanced visualization capabilities, especially for small structures, and opens up new possibilities for detailed three-dimensional imaging. Shunt valves are implanted under the skin and redirect excess cerebrospinal fluid, for example, to the abdominal cavity through a catheter. They play a vital role in regulating cerebrospinal fluid drainage in various pathologies, which can lead to hydrocephalus. Accurate imaging of shunt valves is essential to assess the rate of drainage, as their precise adjustment is a requirement for optimal patient care. This study focused on two adjustable shunt valves, the proGAV 2.0® and M. blue® (manufactured by Miethke, Potsdam, Germany). A comprehensive comparative analysis of PC CT and traditional X-ray techniques was conducted to explore this cutting-edge technology and it demonstrated that routine PC CT can efficiently assess shunt valves’ adjustments. This technology shows promise in enhancing the accurate management of shunt valves used in settings where head scans are already frequently required, such as in the treatment of hydrocephalus.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Phantoms, ImagingTomography, X-Ray ComputedImaging, Three-DimensionalCerebrospinal Fluid ShuntsHumansPhotonsHydrocephalus

Stichwörter der Autor:innen

hydrocephalusphoton countingshuntvalve

Autor:innen und Institutionen

  • Department of Neuroradiology, University Medical Centre Mannheim, Medical Faculty Mannheim, University of Heidelberg, 68167 Mannheim, Germany.
  • Department of Radiation Oncology, University Medical Centre Mannheim, Medical Faculty Mannheim, University of Heidelberg, 68167 Mannheim, Germany.

ORCID-Profile: Anna Klempka, Sven Clausen, Mohamed Ilyes Soltane, Eduardo Ackermann, Christoph Groden

Zitieren

APA

Klempka, A., Clausen, S., Soltane, M. I., Ackermann, E., & Groden, C. (2024). Three-Dimensional Visualization of Shunt Valves with Photon Counting CT and Comparison to Traditional X-ray in a Simple Phantom Model. Tomography. https://doi.org/10.3390/tomography10040043

Vancouver

Klempka A, Clausen S, Soltane MI, Ackermann E, Groden C. Three-Dimensional Visualization of Shunt Valves with Photon Counting CT and Comparison to Traditional X-ray in a Simple Phantom Model. Tomography. 2024. doi:10.3390/tomography10040043

BibTeX
@article{Klempka2024,
  author = {Klempka, Anna and Clausen, Sven and Soltane, Mohamed Ilyes and Ackermann, Eduardo and Groden, Christoph},
  title = {Three-Dimensional Visualization of Shunt Valves with Photon Counting CT and Comparison to Traditional X-ray in a Simple Phantom Model},
  journal = {Tomography},
  year = {2024},
  doi = {10.3390/tomography10040043}
}
Kostenlos starten →