Safety and function of programmable ventriculo-peritoneal shunt valves: An in vitro 7 Tesla magnetic resonance imaging study
PLOS ONE · 2023
DOI: 10.1371/journal.pone.0292666 ↗Kurz gefasst
Fachartikel in der Zeitschrift PLOS ONE, 2023. Verfasst von Bixia Chen und 6 weiteren Autor:innen. Beteiligte Einrichtung: Erwin L. Hahn Institute for Magnetic Resonance Imaging, University Duisburg-Essen, Essen, North Rhine Westphalia, Germany. Hauptthemen laut MEDLINE: Cerebrospinal Fluid Shunts, Hydrocephalus, Ventriculoperitoneal Shunt. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 24 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Deutsche Forschungsgesellschaft, Interne Forschungsförderung Essen (IFORES), University Hospital Essen, University Duisburg-Essen.
Abstract (Originalsprache)
Objective
The quantity of ultra-high field MRI neuroimaging studies has rapidly increased. This study tests function, safety, and image artifacts of two frequently implanted programmable ventriculo-peritoneal (VP) shunt valves in a 7T MRI system.
Methods
All tests were performed using a whole-body 7T MRI system. Three proGAV 2.0 and 3 CODMAN CERTAS® Plus programmable VP-shunt valves were tested in three steps. 1) Deflection angle tests close to the bore opening at the location of a static magnetic field gradient of 3–5 T/m. 2) Valves were fixed on a spherical phantom in 3 positions (a. lateral, b. cranial, c. cranial with 22.5° tilt anteriorly) and assessed for keeping the programmed pressure setting and reprogrammability. 3) Valves were fixed on the phantom and positioned lateral in a radiofrequency head coil. MRI scans were performed for both models, including MPRAGE, GRE and SE sequences.
Results
Deflection angles were moderate (13°, 14°, 13°) for the proGAV valves and close to critical (43°, 43°, 41°) for the CODMAN valves at the test location. Taking a scaling factor of 2–3 for the maximum spatial magnetic field gradient accessible to a patient within the magnet bore into account renders both valves MR unsafe regarding ferromagnetic attraction. The proGAV valves kept the pressure settings in all positions and were reprogrammable in positions a. and b. In position c., reprogrammability was lost. The CODMAN valves changed their pressure setting and reprogrammability was lost in all positions. MR image signal homogeneity was unaltered in the phantom center, artifacts limit the assessability of structures in close vicinity to the valves.
Conclusion
Both tested programmable VP-shunt valves are MR unsafe for 7T systems. Novel programming mechanisms using permanent magnets with sufficient magnetic coercivity or magnet-free mechanisms may allow the development of programmable VP-shunt valves that are conditional for 7T MR systems.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Erwin L. Hahn Institute for Magnetic Resonance Imaging, University Duisburg-Essen, Essen, North Rhine Westphalia, Germany.
- Department of Neurosurgery, University Hospital Essen, University Duisburg-Essen, Essen, North Rhine Westphalia, Germany.
- High-Field and Hybrid MR Imaging, University Hospital Essen, University Duisburg-Essen, Essen, North Rhine Westphalia, Germany.
ORCID-Profile: Bixia Chen, Karsten H Wrede
Förderung
- Deutsche Forschungsgesellschaft
- Interne Forschungsförderung Essen (IFORES), University Hospital Essen, University Duisburg-Essen
Zitieren
APA
Chen, B., Dammann, P., Jabbarli, R., Sure, U., Quick, H. H., Kraff, O., & Wrede, K. H. (2023). Safety and function of programmable ventriculo-peritoneal shunt valves: An in vitro 7 Tesla magnetic resonance imaging study. PLOS ONE. https://doi.org/10.1371/journal.pone.0292666
Vancouver
Chen B, Dammann P, Jabbarli R, Sure U, Quick HH, Kraff O, et al. Safety and function of programmable ventriculo-peritoneal shunt valves: An in vitro 7 Tesla magnetic resonance imaging study. PLOS ONE. 2023. doi:10.1371/journal.pone.0292666
BibTeX
@article{Chen2023,
author = {Chen, Bixia and Dammann, Philipp and Jabbarli, Ramazan and Sure, Ulrich and Quick, Harald H and Kraff, Oliver and Wrede, Karsten H},
title = {Safety and function of programmable ventriculo-peritoneal shunt valves: An in vitro 7 Tesla magnetic resonance imaging study},
journal = {PLOS ONE},
year = {2023},
doi = {10.1371/journal.pone.0292666}
}
EUVIMED