A Portable Electrical Response Verification System for Blood Glucose Meters Based on Dynamic Microcurrent Reproduction

Wenshu Yue, Yifan Li iD, Jinhui Cai iD

Sensors · 2026

DOI: 10.3390/s26185895 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Sensors, 2026. Verfasst von Wenshu Yue und 2 weiteren Autor:innen. Beteiligte Einrichtung: College of Metrology Measurement and Instrument, China Jiliang University, Hangzhou 310018, China. Hauptthemen laut MEDLINE: Blood Glucose, Blood Glucose Self-Monitoring, Biosensing Techniques. Die Arbeit nennt 34 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Key R&D Program of China, National Natural Science Foundation of China.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Portable blood glucose meters are commonly evaluated using test strips and control solutions, which assess the combined meter–strip–reagent response but are not designed to provide a directly controlled, pre-characterized electrical stimulus for repeated meter-side verification. This study developed a portable electrical response verification system based on dynamic microcurrent reproduction using a calibrated programmable current source. At each of two control solution levels, five 1000-point test strip current responses were acquired. Each response was reduced to 100 points by averaging every 10 consecutive samples, and the five reduced responses were then averaged point by point to obtain one level-specific mean reference waveform. Each mean waveform was converted into a 100-point DAC code table for STM32-controlled reproduction. The current source provided a measured output range of 0.016–9.829 μA. Five repeated reproductions per level yielded mean Pearson correlation coefficients of 0.9993 and 0.9995 and peak current CV values of 2.52% and 1.59%, respectively. The corresponding GA-3 meter (Sinocare Inc., Changsha, Hunan, China) readings differed from the mean original readings by 1.70% and 1.18%, with CV values of 1.81% and 1.29%. These results support the feasibility of controlled electrical response verification and short-term repeatability assessment of strip-based blood glucose meters.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Blood GlucoseBlood Glucose Self-MonitoringBiosensing TechniquesHumansElectricity

Stichwörter der Autor:innen

DAC code tableblood glucose meterdynamic microcurrent reproductionelectrical response verificationprogrammable current source

Substanzen

Blood Glucose

Autor:innen und Institutionen

  • College of Metrology Measurement and Instrument, China Jiliang University, Hangzhou 310018, China.

ORCID-Profile: Yifan Li, Jinhui Cai

Förderung

  • National Key R&D Program of China
  • National Natural Science Foundation of China

Zitieren

APA

Yue, W., Li, Y., & Cai, J. (2026). A Portable Electrical Response Verification System for Blood Glucose Meters Based on Dynamic Microcurrent Reproduction. Sensors. https://doi.org/10.3390/s26185895

Vancouver

Yue W, Li Y, Cai J. A Portable Electrical Response Verification System for Blood Glucose Meters Based on Dynamic Microcurrent Reproduction. Sensors. 2026. doi:10.3390/s26185895

BibTeX
@article{Yue2026,
  author = {Yue, Wenshu and Li, Yifan and Cai, Jinhui},
  title = {A Portable Electrical Response Verification System for Blood Glucose Meters Based on Dynamic Microcurrent Reproduction},
  journal = {Sensors},
  year = {2026},
  doi = {10.3390/s26185895}
}
Kostenlos starten →