EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

A wearable microneedle patch incorporating reversible FRET-based hydrogel sensors for continuous glucose monitoring

Yubing Hu, Zhisheng Pan, Marieke De Bock, Tai Xuan Tan, Yuhuai Wang, Yuqi Shi, Neng Yan, Ali K Yetisen

Biosensors and Bioelectronics · 2024-10 · 262 · 116542

DOI: 10.1016/j.bios.2024.116542 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biosensors and Bioelectronics, 2024-10. Verfasst von Yubing Hu und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Chemical Engineering, Imperial College London, London, SW7 2AZ, United Kingdom. Electronic address: yubing.hu@imperial.ac.uk. Hauptthemen laut MEDLINE: Fluorescence Resonance Energy Transfer, Biosensing Techniques, Hydrogels, Blood Glucose Self-Monitoring. Die Arbeit wurde bisher 77-mal zitiert (Crossref) und nennt 47 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Engineering and Physical Sciences Research Council.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Continuous glucose monitors are crucial for diabetes management, but invasive sampling, signal drift and frequent calibrations restrict their widespread usage. Microneedle sensors are emerging as a minimally-invasive platform for real-time monitoring of clinical parameters in interstitial fluid. Herein, a painless and flexible microneedle sensing patch is constructed by a mechanically-strong microneedle base and a thin layer of fluorescent hydrogel sensor for on-site, accurate, and continuous glucose monitoring. The Förster resonance energy transfer (FRET)-based hydrogel sensors are fabricated by facile photopolymerizations of acryloylated FRET pairs and glucose-specific phenylboronic acid. The optimized hydrogel sensor enables quantification of glucose with reversibility, high selectivity, and signal stability against photobleaching. Poly (ethylene glycol diacrylate)-co-polyacrylamide hydrogel is utilized as the microneedle base, facilitating effective skin piercing and biofluid extraction. The integrated microneedle sensor patch displays a sensitivity of 0.029 mM-1 in the (patho)physiological range, a low detection limit of 0.193 mM, and a response time of 7.7 min in human serum. Hypoglycemia, euglycemia and hyperglycemia are continuously monitored over 6 h simulated meal and rest activities in a porcine skin model. This microneedle sensor with high transdermal analytical performance offers a powerful tool for continuous diabetes monitoring at point-of-care settings.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Fluorescence Resonance Energy TransferBiosensing TechniquesHydrogelsBlood Glucose Self-MonitoringNeedlesBlood GlucoseWearable Electronic DevicesHumansAnimalsSwinePolyethylene GlycolsLimit of DetectionAcrylic ResinsEquipment DesignContinuous Glucose MonitoringBoronic AcidsPolyacrylamides

Stichwörter der Autor:innen

Continuous glucose monitoringFRETFluorescent sensorsHydrogelsMicroneedles

Substanzen

HydrogelsBlood GlucosePolyethylene GlycolsAcrylic ResinsBoronic AcidsPolyacrylamidesbenzeneboronic acid

Autor:innen und Institutionen

  • Department of Chemical Engineering, Imperial College London, London, SW7 2AZ, United Kingdom. Electronic address: yubing.hu@imperial.ac.uk.
  • Department of Chemical Engineering, Imperial College London, London, SW7 2AZ, United Kingdom.
  • Department of Chemical Engineering, Massachusetts Institute of Technology, Cambridge, MA, 02139, United States.
  • State Environmental Protection Key Laboratory of Source Apportionment and Control of Aquatic Pollution, School of Environmental Studies, China University of Geosciences, Wuhan, 430074, China.
  • Department of Chemical Engineering, Imperial College London, London, SW7 2AZ, United Kingdom. Electronic address: a.yetisen@imperial.ac.uk.

Förderung

  • Engineering and Physical Sciences Research Council

Zitieren

APA

Hu, Y., Pan, Z., De Bock, M., Tan, T. X., Wang, Y., Shi, Y., Yan, N., & Yetisen, A. K. (2024). A wearable microneedle patch incorporating reversible FRET-based hydrogel sensors for continuous glucose monitoring. Biosensors and Bioelectronics, 262, 116542. https://doi.org/10.1016/j.bios.2024.116542

Vancouver

Hu Y, Pan Z, De Bock M, Tan TX, Wang Y, Shi Y, et al. A wearable microneedle patch incorporating reversible FRET-based hydrogel sensors for continuous glucose monitoring. Biosensors and Bioelectronics. 2024;262:116542. doi:10.1016/j.bios.2024.116542

BibTeX
@article{Hu2024,
  author = {Hu, Yubing and Pan, Zhisheng and De Bock, Marieke and Tan, Tai Xuan and Wang, Yuhuai and Shi, Yuqi and Yan, Neng and Yetisen, Ali K},
  title = {A wearable microneedle patch incorporating reversible FRET-based hydrogel sensors for continuous glucose monitoring},
  journal = {Biosensors and Bioelectronics},
  year = {2024},
  volume = {262},
  pages = {116542},
  doi = {10.1016/j.bios.2024.116542}
}
Kostenlos starten →