A Deep Sparse Capsule Network for Non-Invasive Blood Glucose Level Estimation Using a PPG Sensor
Sensors · 2025
DOI: 10.3390/s25061868 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, 2025. Verfasst von Narmatha Chellamani und 8 weiteren Autor:innen. Beteiligte Einrichtung: Faculty of Computers and Information Technology, University of Tabuk, Tabuk 71491, Saudi Arabia. Hauptthemen laut MEDLINE: Photoplethysmography, Blood Glucose, Blood Glucose Self-Monitoring. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 33 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: University of Tabuk, Deanship of Research and Graduate Studies at the University of Tabuk.
Abstract (Originalsprache)
Diabetes, a chronic medical condition, affects millions of people worldwide and requires consistent monitoring of blood glucose levels (BGLs). Traditional invasive methods for BGL monitoring can be challenging and painful for patients. This study introduces a non-invasive, deep learning (DL)-based approach to estimate BGL using photoplethysmography (PPG) signals. Specifically, a Deep Sparse Capsule Network (DSCNet) model is proposed to provide accurate and robust BGL monitoring. The proposed model’s workflow includes data collection, preprocessing, feature extraction, and predictions. A hardware module was designed using a PPG sensor and Raspberry Pi to collect patient data. In preprocessing, a Savitzky–Golay filter and moving average filter were applied to remove noise and preserve pulse form and high-frequency components. The DSCNet model was then applied to predict the sugar level. Two models were developed for prediction: a baseline model, DSCNet, and an enhanced model, DSCNet with self-attention. DSCNet’s performance was evaluated using Mean Absolute Percentage Error (MAPE), Mean Absolute Error (MAE), Mean Squared Error (MSE), Root Mean Squared Error (RMSE), Mean Absolute Relative Difference (MARD), and coefficient of determination (R2), yielding values of 3.022, 0.05, 0.058, 0.062, 10.81, and 0.98, respectively.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Faculty of Computers and Information Technology, University of Tabuk, Tabuk 71491, Saudi Arabia.
- Department of Pharmacy Practice, Faculty of Pharmacy, University of Tabuk, Tabuk 71491, Saudi Arabia.
- Biostatistics & Data Science, LSU Health Sciences Center New Orleans, New Orleans, LA 70112, USA.
ORCID-Profile: Narmatha Chellamani, Manimurugan Shanmuganathan, Palanisamy Amirthalingam, Emad Muteb Alharbi, Hibah Qasem Salman Alatawi, Kousalya Prabahar, Anand Paul
Förderung
- University of Tabuk
- Deanship of Research and Graduate Studies at the University of Tabuk
Zitieren
APA
Chellamani, N., Albelwi, S. A., Shanmuganathan, M., Amirthalingam, P., Alharbi, E. M., Alatawi, H. Q. S., Prabahar, K., Aljabri, J. B., & Paul, A. (2025). A Deep Sparse Capsule Network for Non-Invasive Blood Glucose Level Estimation Using a PPG Sensor. Sensors. https://doi.org/10.3390/s25061868
Vancouver
Chellamani N, Albelwi SA, Shanmuganathan M, Amirthalingam P, Alharbi EM, Alatawi HQS, et al. A Deep Sparse Capsule Network for Non-Invasive Blood Glucose Level Estimation Using a PPG Sensor. Sensors. 2025. doi:10.3390/s25061868
BibTeX
@article{Chellamani2025,
author = {Chellamani, Narmatha and Albelwi, Saleh Ali and Shanmuganathan, Manimurugan and Amirthalingam, Palanisamy and Alharbi, Emad Muteb and Alatawi, Hibah Qasem Salman and Prabahar, Kousalya and Aljabri, Jawhara Bader and Paul, Anand},
title = {A Deep Sparse Capsule Network for Non-Invasive Blood Glucose Level Estimation Using a PPG Sensor},
journal = {Sensors},
year = {2025},
doi = {10.3390/s25061868}
}