Panoramic Near-Infrared Imaging Device for Peripheral Vascular Mapping
Sensors · 03.08.2026 · 26 (15) · 4895
DOI: 10.3390/s26154895 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, online erschienen am 03.08.2026. Verfasst von Bendegúz Juhos und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Interventional Radiology, Heart and Vascular Centre, Semmelweis University, 1122 Budapest, Hungary. Hauptthemen laut MEDLINE: Imaging, Three-Dimensional, Veins. Die Arbeit nennt 32 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Ministry for Culture and Innovation, National Research, Development and Innovation Office, Hungarian Academy of Sciences.
Abstract (Originalsprache)
Longitudinal mapping of the superficial peripheral vascular network is clinically relevant for conditions such as venous insufficiency, superficial venous thrombosis, and localized hemorrhagic injury; yet existing modalities are either operator-dependent, costly, or unable to provide wide-field coverage. We designed and demonstrated the feasibility of a relatively quick, cost-effective, automated panoramic near-infrared (NIR) imaging system operating at 850 nm, with a total acquisition time of 30 s. The prototype integrates a motorized rotational acquisition frame, co-localized illumination, lateral mirror enhancement, and a time-of-flight ranging sensor. A custom image processing pipeline combining contrast-limited adaptive histogram equalization (CLAHE), black-hat morphological filtering, Otsu binarization, structure-tensor-based diameter quantification, and photogrammetric 3D reconstruction was applied to data from five healthy volunteers. Optimal acquisition parameters (30 ms exposure, analog gain 3.5) were identified via systematic characterization. The pipeline reliably isolated venous structures of the 35 cm field of view, yielding a mean superficial vein diameter of 2.69 ± 1.48 mm, consistent with published anatomical references. A panoramic texture-mapped 3D surface reconstruction of the limb was generated for each participant. The system provides a rapid, operator-independent panoramic view of superficial veins suitable for future longitudinal monitoring, offering a compelling complementary tool to duplex ultrasound for tracking morphological and volumetric vascular changes.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Interventional Radiology, Heart and Vascular Centre, Semmelweis University, 1122 Budapest, Hungary.
- Department of Electronics, Information and Bioengineering, Politecnico di Milano, 20133 Milano, Italy.
ORCID-Profile: Bendegúz Juhos, Imre Vida, Csaba Csobay-Novák
Förderung
- Ministry for Culture and Innovation
- National Research, Development and Innovation Office
- Hungarian Academy of Sciences
Zitieren
APA
Juhos, B., Vida, I., & Csobay-Novák, C. (2026). Panoramic Near-Infrared Imaging Device for Peripheral Vascular Mapping. Sensors, 26(15), 4895. https://doi.org/10.3390/s26154895
Vancouver
Juhos B, Vida I, Csobay-Novák C. Panoramic Near-Infrared Imaging Device for Peripheral Vascular Mapping. Sensors. 2026;26(15):4895. doi:10.3390/s26154895
BibTeX
@article{Juhos2026,
author = {Juhos, Bendegúz and Vida, Imre and Csobay-Novák, Csaba},
title = {Panoramic Near-Infrared Imaging Device for Peripheral Vascular Mapping},
journal = {Sensors},
year = {2026},
volume = {26},
number = {15},
pages = {4895},
doi = {10.3390/s26154895}
}
EUVIMED