EUVIMEDEUVIMED entdecken
Crossref

Slow‐Flow‐Sensitive Artery‐Vein‐Separated Velocity Mapping ( SAM ) Phase Contrast MR Angiography: Initial Evaluation of Hand Vasculature

Xin Guo iD, Zhang Shi, Bingyi Wang iD, Weirui Cai, Bei Wang, Shaokang Wen, Xijing Zhang, Jiayu Zhu, Jianmin Yuan, Xianghua Fan, Zhensen Chen, He Wang und 1 weitere

Magnetic Resonance in Medicine · 2026

DOI: 10.1002/mrm.70375 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, 2026. Verfasst von Xin Guo und 12 weiteren Autor:innen. Beteiligte Einrichtung: Institute of Science and Technology for Brain-Inspired Intelligence, Fudan University, Shanghai, China. Hauptthemen laut MEDLINE: Magnetic Resonance Angiography, Hand, Veins, Arteries. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 26 Literaturangaben. Gefördert von: Shanghai Science and Technology Commission "Explorer Project", National Natural Science Foundation of China.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

To develop a non‐contrast‐enhanced MR angiography method for imaging slow‐flow hand vessels that enables flow velocity measurement and artery–vein separation.

Methods

A slow‐flow‐sensitive artery–vein‐separated velocity mapping phase‐contrast MR angiography (SAM PC‐MRA) technique was developed, employing multiple velocity encodings (VENCs). Ultra‐low VENC acquisitions enhanced visualization of slow‐flow vasculature, while high‐VENC acquisitions enabled velocity mapping and artery–vein separation based on flow direction. MRA was performed on a 5 T MR system in 20 healthy volunteers and one patient with vasculitis. Vessel delineation scores, signal‐to‐noise ratio (SNR), contrast‐to‐noise ratio (CNR), and vascular morphology metrics were compared with conventional 3D PC‐MRA at VENCs of 5 and 10 cm/s. Flow velocity measurements were validated against 2D PC.

Results

SAM‐PC demonstrated superior visualization of small vessels with reliable artery–vein separation and flow velocity mapping. Across healthy volunteers, vessel delineation scores were significantly higher with SAM‐PC compared with 3D PC at VENCs of 5 and 10 cm/s (3.9 vs. 3.3 vs. 2.9, p < 0.001), with average SNR increasing by 37.6% and 74.8% and CNR by 69.8% and 131.2%. More vessels were detected (16 571 vs. 10 132 vs. 7856, p < 0.001), and flow velocity showed no significant difference from 2D PC ( p = 0.389, r = 0.835). SAM‐PC in the vasculitis patient demonstrated an absence of blood flow in the necrotic fingers.

Conclusions

SAM PC‐MRA enables high‐resolution visualization of slow‐flow hand vessels with accurate time‐averaged flow quantification and artery–vein separation.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Magnetic Resonance AngiographyHandVeinsArteriesHumansAdultMaleFemaleBlood Flow VelocityReproducibility of ResultsSignal-To-Noise RatioImage Processing, Computer-AssistedMiddle AgedYoung AdultImaging, Three-DimensionalAlgorithms

Stichwörter der Autor:innen

artery–vein separationflow velocity mappinghandmultiple VENCsnon‐contrast‐enhanced MRAphase contrast

Autor:innen und Institutionen

  • Institute of Science and Technology for Brain-Inspired Intelligence, Fudan University, Shanghai, China.
  • Department of Radiology, Zhongshan Hospital, Fudan University, Shanghai, China.
  • Shanghai Institute of Medical Imaging, Shanghai, China.
  • Shanghai United Imaging Healthcare Co. Ltd., Shanghai, China.

ORCID-Profile: Xin Guo, Bingyi Wang, Hao Li

Förderung

  • Shanghai Science and Technology Commission "Explorer Project"
  • National Natural Science Foundation of China

Zitieren

APA

Guo, X., Shi, Z., Wang, B., Cai, W., Wang, B., Wen, S., Zhang, X., Zhu, J., Yuan, J., Fan, X., Chen, Z., Wang, H., & Li, H. (2026). Slow‐Flow‐Sensitive Artery‐Vein‐Separated Velocity Mapping ( SAM ) Phase Contrast MR Angiography: Initial Evaluation of Hand Vasculature. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.70375

Vancouver

Guo X, Shi Z, Wang B, Cai W, Wang B, Wen S, et al. Slow‐Flow‐Sensitive Artery‐Vein‐Separated Velocity Mapping ( SAM ) Phase Contrast MR Angiography: Initial Evaluation of Hand Vasculature. Magnetic Resonance in Medicine. 2026. doi:10.1002/mrm.70375

BibTeX
@article{Guo2026,
  author = {Guo, Xin and Shi, Zhang and Wang, Bingyi and Cai, Weirui and Wang, Bei and Wen, Shaokang and Zhang, Xijing and Zhu, Jiayu and Yuan, Jianmin and Fan, Xianghua and Chen, Zhensen and Wang, He and Li, Hao},
  title = {Slow‐Flow‐Sensitive Artery‐Vein‐Separated Velocity Mapping ( SAM ) Phase Contrast MR Angiography: Initial Evaluation of Hand Vasculature},
  journal = {Magnetic Resonance in Medicine},
  year = {2026},
  doi = {10.1002/mrm.70375}
}
Kostenlos starten →