EUVIMEDEUVIMED entdecken
Crossref

Performance verification of blood vessel detection system using near-infrared light

Jieun Park iD, Junghun Kim iD

Technology and Health Care · 2026

DOI: 10.1177/09287329251414328 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Technology and Health Care, 2026. Verfasst von Jieun Park und 1 weiteren Autor:innen. Beteiligte Einrichtung: School of Computer Software, Daegu Catholic University, Gyeongsan-si, Gyeongbuk, Republic of Korea. Hauptthemen laut MEDLINE: Infrared Rays, Blood Vessels, Veins. Die Arbeit nennt 16 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Near-infrared (NIR) imaging technology has been increasingly applied in clinical and biomedical engineering fields for subcutaneous vein detection and vascular guidance. However, most existing systems still face limitations such as inconsistent visualization under various skin tones and difficulties in achieving real-time projection alignment.

Objective

The objective of this study is to develop a near-infrared (NIR)-based vascular detection system and to evaluate its performance.

Methods

The developed system provides intuitive visualization by projecting vascular images in real time onto the same skin region. Performance validation was conducted using a vascular model and the abdominal vessels of rabbits.

Results

In the vascular model experiment, the localization accuracy was 98.9%, and in the rabbit experiment, the detection success rate for vessels with a diameter of ≥1 mm was 100%.

Conclusions

The proposed method was confirmed to reduce the time required for acquiring anatomical knowledge and to minimize complications by preventing incorrect venipuncture.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Infrared RaysBlood VesselsVeinsAnimalsRabbitsSpectroscopy, Near-Infrared

Stichwörter der Autor:innen

Near-infrared lightinjection assistantintravenous injectionsubcutaneous detectorvein visualization

Autor:innen und Institutionen

  • School of Computer Software, Daegu Catholic University, Gyeongsan-si, Gyeongbuk, Republic of Korea.

ORCID-Profile: Jieun Park, Junghun Kim

Zitieren

APA

Park, J., & Kim, J. (2026). Performance verification of blood vessel detection system using near-infrared light. Technology and Health Care. https://doi.org/10.1177/09287329251414328

Vancouver

Park J, Kim J. Performance verification of blood vessel detection system using near-infrared light. Technology and Health Care. 2026. doi:10.1177/09287329251414328

BibTeX
@article{Park2026,
  author = {Park, Jieun and Kim, Junghun},
  title = {Performance verification of blood vessel detection system using near-infrared light},
  journal = {Technology and Health Care},
  year = {2026},
  doi = {10.1177/09287329251414328}
}
Kostenlos starten →