Validation of IMU-Based Insoles (LUBU) for the Estimation of Gait Spatio-Temporal Parameters
Sensors · 2026-07-28 · 26 (15) · 4792
DOI: 10.3390/s26154792 ↗At a glance
Journal article in Sensors, published online on 2026-07-28. Written by Chiara Orsanigo and 3 co-authors. Institution: Department of Electronics, Information and Bioengineering, Politecnico di Milano, Piazza Leonardo da Vinci 32, 20133 Milan, Italy. Major MEDLINE topics: Gait, Gait Analysis. 22 references. The full text is freely available (open access, CC BY 4.0).
Abstract (original language)
Gait analysis is a well-known tool used to evaluate human locomotion. This analysis is usually performed in movement analysis laboratories equipped with optoelectronic cameras. However, many wearable devices based on the use of Inertial Measurement Units (IMUs) have been developed to overcome the limitations of the gold standard technology. LUBU Technologies developed insoles equipped with IMUs and algorithms for the extraction of gait parameters such as gait events, temporal parameters and stride length. The aim of the present study was the validation of these parameters against an optoelectronic reference system. Twenty people were involved in performing a series of indoor walking trials to assess the accuracy of the insole measurements and an additional group of ten people were asked to walk outdoors to preliminarily assess total distance estimation under ecological walking conditions. The results showed low errors and good agreement for all the parameters computed by the insoles. Moreover, the outdoor assessment offered preliminary insights into performance in a more ecological setting. Overall, the findings suggest that LUBU insoles may represent a valid wearable tool for estimating gait spatio-temporal parameters in healthy young adults. However, further investigations are required in older adults or populations with pathological gait patterns.
Subjects
MeSH terms (MEDLINE)
Author keywords
Authors and institutions
- Department of Electronics, Information and Bioengineering, Politecnico di Milano, Piazza Leonardo da Vinci 32, 20133 Milan, Italy.
- Department of Occupational and Environmental Medicine, Epidemiology and Hygiene, Italian National Institute for Insurance Against Accidents at Work (INAIL), Via Fontana Candida 1, Monte Porzio Catone, 00078 Rome, Italy.
ORCID profiles: Filippo Motta, Manuela Galli
Cite
APA
Orsanigo, C., Motta, F., Milazzo, A. G., & Galli, M. (2026). Validation of IMU-Based Insoles (LUBU) for the Estimation of Gait Spatio-Temporal Parameters. Sensors, 26(15), 4792. https://doi.org/10.3390/s26154792
Vancouver
Orsanigo C, Motta F, Milazzo AG, Galli M. Validation of IMU-Based Insoles (LUBU) for the Estimation of Gait Spatio-Temporal Parameters. Sensors. 2026;26(15):4792. doi:10.3390/s26154792
BibTeX
@article{Orsanigo2026,
author = {Orsanigo, Chiara and Motta, Filippo and Milazzo, Alessandro Giuseppe and Galli, Manuela},
title = {Validation of IMU-Based Insoles (LUBU) for the Estimation of Gait Spatio-Temporal Parameters},
journal = {Sensors},
year = {2026},
volume = {26},
number = {15},
pages = {4792},
doi = {10.3390/s26154792}
}
EUVIMED