EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Every Step Counts—How Can We Accurately Count Steps with Wearable Sensors During Activities of Daily Living in Individuals with Neurological Conditions?

Florence Crozat, Johannes Pohl, Chris Easthope Awai iD, Christoph Michael Bauer, Roman Peter Kuster iD

Sensors · 2025

DOI: 10.3390/s25185657 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Sensors, 2025. Verfasst von Florence Crozat und 4 weiteren Autor:innen. Beteiligte Einrichtung: Therapy Science Lab, Lake Lucerne Institute, 6354 Vitznau, Switzerland. Hauptthemen laut MEDLINE: Activities of Daily Living, Wearable Electronic Devices, Nervous System Diseases. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 64 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Wearable sensors provide objective, continuous, and non-invasive quantification of physical activity, with step count serving as one of the most intuitive measures. However, significant gait alterations in individuals with neurological conditions limit the accuracy of step-counting algorithms trained on able-bodied individuals. Therefore, this study investigates the accuracy of step counting during activities of daily living (ADL) in a neurological population. Seven individuals with neurological conditions wore seven accelerometers while performing ADL for 30 min. Step events manually annotated from video served as ground truth. An optimal sensing and analysis configuration for machine learning algorithm development (sensor location, filter range, window length, and regressor type) was identified and compared to existing algorithms developed for able-bodied individuals. The most accurate configuration includes a waist-worn sensor, a 0.5–3 Hz bandpass filter, a 5 s window, and gradient boosting regression. The corresponding algorithm showed a significantly lower error rate compared to existing algorithms trained on able-bodied data. Notably, all algorithms undercounted steps. This study identified an optimal sensing and analysis configuration for machine learning-based step counting in a neurological population and highlights the limitations of applying able-bodied-trained algorithms. Future research should focus on developing accurate and robust step-counting algorithms tailored to individuals with neurological conditions.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Activities of Daily LivingWearable Electronic DevicesNervous System DiseasesHumansAlgorithmsMaleMachine LearningFemaleAdultMiddle AgedAccelerometryGaitExerciseAgedWalking

Stichwörter der Autor:innen

accelerometeraccuracyactivities of daily livingalgorithm developmentinertial measurement unitmachine learningneurological populationpopulation-specific algorithmstep countvalidation

Autor:innen und Institutionen

  • Therapy Science Lab, Lake Lucerne Institute, 6354 Vitznau, Switzerland.
  • Data Analytics & Rehabilitation Technology (DART), Lake Lucerne Institute, 6354 Vitznau, Switzerland.

ORCID-Profile: Chris Easthope Awai, Roman Peter Kuster

Zitieren

APA

Crozat, F., Pohl, J., Easthope Awai, C., Bauer, C. M., & Kuster, R. P. (2025). Every Step Counts—How Can We Accurately Count Steps with Wearable Sensors During Activities of Daily Living in Individuals with Neurological Conditions?. Sensors. https://doi.org/10.3390/s25185657

Vancouver

Crozat F, Pohl J, Easthope Awai C, Bauer CM, Kuster RP. Every Step Counts—How Can We Accurately Count Steps with Wearable Sensors During Activities of Daily Living in Individuals with Neurological Conditions?. Sensors. 2025. doi:10.3390/s25185657

BibTeX
@article{Crozat2025,
  author = {Crozat, Florence and Pohl, Johannes and Easthope Awai, Chris and Bauer, Christoph Michael and Kuster, Roman Peter},
  title = {Every Step Counts—How Can We Accurately Count Steps with Wearable Sensors During Activities of Daily Living in Individuals with Neurological Conditions?},
  journal = {Sensors},
  year = {2025},
  doi = {10.3390/s25185657}
}
Infokarte | EUVIMED

Artikeldaten derzeit nicht verfügbar.

Recherche