EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

A Sensor to Analyze Fish Freshness: A Virtual Sensor Array Based on an Electrochemical Chemotransistor

Yulia Efremenko, Eya Boughanmi iD, Vladimir M Mirsky iD

Sensors · 07.07.2026 · 26 (13) · 4306

DOI: 10.3390/s26134306 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Sensors, online erschienen am 07.07.2026. Verfasst von Yulia Efremenko und 2 weiteren Autor:innen. Beteiligte Einrichtung: Nanobiotechnology Department, Institute of Biotechnology, Brandenburg University of Technology Cottbus-Senftenberg, 01968 Senftenberg, Germany. Hauptthemen laut MEDLINE: Fishes, Electrochemical Techniques, Biosensing Techniques. Die Arbeit nennt 69 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: European Union, EU, DAAD.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The introduction of a quantitative definition of fish freshness enables the determination of the remaining storage time of raw fish materials. To measure this value, a virtual array of electrochemical chemotransistor-based chemical sensors was developed. The electrolyte used to electrically connect the four measurement electrodes and the reference electrode was optimized. To achieve the high stability, high electrochemical activity of chemosensitive material, and reversible potential of the silver/silver chloride reference electrode, a chloride-containing ionic liquid and polymeric acid mixture was used as the electrolyte. Polyaniline in different redox states was applied as the chemosensitive material with electrically controlled affinity. First, the sensor was evaluated for trimethylammonium detection, and then it was applied to fish samples. Unlike the response observed for trimethylammonium, the sensor’s response to fish samples exhibited complex, non-exponential kinetics and a non-monotonic dependence on the storage duration of fish samples. To characterize these responses, a set of descriptors was introduced. The storage time was estimated by minimizing the Euclidean distance between the descriptors values obtained from fish samples and those determined during calibration. Based on the quantitative definition of freshness, this approach categorizes the current stage of fish products and predicts the remaining storage duration quantitatively.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

FishesElectrochemical TechniquesBiosensing TechniquesAnimalsElectrodesIonic Liquids

Stichwörter der Autor:innen

affinity controlartificial nosechemometricsconductometric sensorelectrochemical chemotransistorfish freshnessionic liquidsvirtual sensor array

Substanzen

Ionic Liquids

Autor:innen und Institutionen

  • Nanobiotechnology Department, Institute of Biotechnology, Brandenburg University of Technology Cottbus-Senftenberg, 01968 Senftenberg, Germany.
  • Analytical Chemistry and Electrochemistry Lab, Faculty of Science, University of Tunis El Manar, Tunis 2092, Tunisia.

ORCID-Profile: Eya Boughanmi, Vladimir M Mirsky

Förderung

  • European Union
  • EU
  • DAAD

Zitieren

APA

Efremenko, Y., Boughanmi, E., & Mirsky, V. M. (2026). A Sensor to Analyze Fish Freshness: A Virtual Sensor Array Based on an Electrochemical Chemotransistor. Sensors, 26(13), 4306. https://doi.org/10.3390/s26134306

Vancouver

Efremenko Y, Boughanmi E, Mirsky VM. A Sensor to Analyze Fish Freshness: A Virtual Sensor Array Based on an Electrochemical Chemotransistor. Sensors. 2026;26(13):4306. doi:10.3390/s26134306

BibTeX
@article{Efremenko2026,
  author = {Efremenko, Yulia and Boughanmi, Eya and Mirsky, Vladimir M},
  title = {A Sensor to Analyze Fish Freshness: A Virtual Sensor Array Based on an Electrochemical Chemotransistor},
  journal = {Sensors},
  year = {2026},
  volume = {26},
  number = {13},
  pages = {4306},
  doi = {10.3390/s26134306}
}
Kostenlos starten →