EUVIMEDEUVIMED entdecken
Crossref

Disposable biosensor based on nanodiamond particles, ionic liquid and poly-l-lysine for determination of phenolic compounds

Damla Şener, Pınar Esra Erden, Ceren Kaçar Selvi

Analytical Biochemistry · 2024

DOI: 10.1016/j.ab.2024.115464 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Analytical Biochemistry, 2024. Verfasst von Damla Şener und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Chemistry, Polatlı Faculty of Science and Letters, Ankara Haci Bayram Veli University, Ankara, Türkiye. Hauptthemen laut MEDLINE: Nanodiamonds, Ionic Liquids, Biosensing Techniques. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 44 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This study describes the development of a highly sensitive amperometric biosensor for the analysis of phenolic compounds such as catechol. The biosensor architecture is based on the immobilization of tyrosinase (Tyr) on a screen-printed carbon electrode (SPE) modified with nanodiamond particles (ND), 1-butyl-3-methylimidazolium hexafluorophosphate (IL) and poly-l-lysine (PLL). Surface morphologies of the electrodes during the modification process were evaluated by scanning electron microscopy (SEM) and energy-dispersive X-ray spectroscopy (EDX). Cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS) were used to investigate the electrochemical characteristics of the modified electrodes. Owing to the synergistic effect of the modification materials, the Tyr/PLL/ND-IL/SPE exhibited high sensitivity (328.2 μA mM-1) towards catechol with a wide linear range (5.0 × 10-8 - 1.2 × 10-5 M) and low detection limit (1.1 × 10-8 M). Furthermore, the method demonstrated good reproducibility and stability. The amperometric response of the biosensor towards other phenolic compounds such as bisphenol A, phenol, p-nitrophenol, m-cresol, p-cresol and o-cresol was also investigated. The analytical applicability of the biosensor was tested by the analysis of catechol in tap water. The results of the tap water analysis showed that the Tyr/PLL/ND-IL/SPE can be used as a practical and effective method for catechol determination.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

NanodiamondsIonic LiquidsBiosensing TechniquesPolylysineReproducibility of ResultsPhenolsCatecholsMonophenol MonooxygenaseCarbonWaterElectrodesElectrochemical Techniques

Stichwörter der Autor:innen

Amperometric biosensorCatecholIonic liquidNanodiamondPhenolic compoundPoly-l-lysine

Substanzen

NanodiamondsIonic LiquidsPolylysinePhenolscatecholCatecholsMonophenol MonooxygenaseCarbonWater

Autor:innen und Institutionen

  • Department of Chemistry, Polatlı Faculty of Science and Letters, Ankara Haci Bayram Veli University, Ankara, Türkiye.
  • Department of Chemistry, Polatlı Faculty of Science and Letters, Ankara Haci Bayram Veli University, Ankara, Türkiye. Electronic address: erdenpe@gmail.com.
  • Department of Chemistry, Faculty of Science, Ankara University, Ankara, Türkiye.

Zitieren

APA

Şener, D., Erden, P. E., & Kaçar Selvi, C. (2024). Disposable biosensor based on nanodiamond particles, ionic liquid and poly-l-lysine for determination of phenolic compounds. Analytical Biochemistry. https://doi.org/10.1016/j.ab.2024.115464

Vancouver

Şener D, Erden PE, Kaçar Selvi C. Disposable biosensor based on nanodiamond particles, ionic liquid and poly-l-lysine for determination of phenolic compounds. Analytical Biochemistry. 2024. doi:10.1016/j.ab.2024.115464

BibTeX
@article{ener2024,
  author = {Şener, Damla and Erden, Pınar Esra and Kaçar Selvi, Ceren},
  title = {Disposable biosensor based on nanodiamond particles, ionic liquid and poly-l-lysine for determination of phenolic compounds},
  journal = {Analytical Biochemistry},
  year = {2024},
  doi = {10.1016/j.ab.2024.115464}
}
Kostenlos starten →