Fachartikel in der Zeitschrift Microchimica Acta, 2026. Verfasst von Huseyin Senturk und 1 weiteren Autor:innen. Beteiligte Einrichtung: Department of Analytical Chemistry, Faculty of Pharmacy, Ege University, 35040, Izmir, Türkiye. Hauptthemen laut MEDLINE: Nanotubes, Carbon, Aptamers, Nucleotide, Ionic Liquids, Spike Glycoprotein, Coronavirus. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 54 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Ege University.
Abstract (Originalsprache)
An aptamer-based electrochemical biosensor was developed for the highly sensitive detection of SARS-CoV-2 S1 protein using electrodes modified with a multi-walled carbon nanotube–ionic liquid (MWCNT–IL) composite. Comprehensive electrochemical and microscopic characterizations of the MWCNT–IL material were conducted, followed by the optimization of experimental parameters including ionic liquid concentration and surface modification time. Critical parameters for aptasensor construction, aptamer concentration, immobilization time, and aptamer-protein interaction time, were also optimized. Under optimal conditions, the biosensor exhibited a wide linear response from 1 fg/mL to 1 ng/mL in buffer, with a remarkably low limit of detection (LOD) of 0.11 fg/mL. Selectivity evaluations against hemagglutinin antigen (HA) and MERS-CoV-S1 (MERS) protein confirmed the sensor’s high specificity for SARS-CoV-2 S1 protein. The sensor’s applicability in artificial saliva was also successfully demonstrated, yielding accurate quantification and low detection limits (LOD: 0.16 fg/mL). Recovery studies in artificial saliva demonstrated satisfactory accuracy, with recoveries ranging from 108% to 120% and high reproducibility. Notably, the aptasensor maintained strong selectivity even in the presence of matrix interferents. Furthermore, the potential for point-of-care use was assessed via a smartphone-connected portable potentiostat. This handheld system enabled a linear detection range of 1 fg/mL to 1 ng/mL with a LOD of 0.83 fg/mL. Collectively, these results highlight the MWCNT–IL-based aptasensor as a robust, low-cost, and portable platform for rapid COVID-19 diagnostics, offering considerable promise for deployment in point-of-care and resource-constrained environments.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Analytical Chemistry, Faculty of Pharmacy, Ege University, 35040, Izmir, Türkiye.
- Department of Analytical Chemistry, Faculty of Pharmacy, Ege University, 35040, Izmir, Türkiye. arzum.erdem@ege.edu.tr.
ORCID-Profile: Huseyin Senturk, Arzum Erdem
Förderung
- Ege University
Zitieren
APA
Senturk, H., & Erdem, A. (2026). A smartphone-integrated aptasensor for SARS-CoV-2 S1 protein using multi-walled carbon nanotube–ionic liquid modified electrodes. Microchimica Acta. https://doi.org/10.1007/s00604-026-07918-7
Vancouver
Senturk H, Erdem A. A smartphone-integrated aptasensor for SARS-CoV-2 S1 protein using multi-walled carbon nanotube–ionic liquid modified electrodes. Microchimica Acta. 2026. doi:10.1007/s00604-026-07918-7
BibTeX
@article{Senturk2026,
author = {Senturk, Huseyin and Erdem, Arzum},
title = {A smartphone-integrated aptasensor for SARS-CoV-2 S1 protein using multi-walled carbon nanotube–ionic liquid modified electrodes},
journal = {Microchimica Acta},
year = {2026},
doi = {10.1007/s00604-026-07918-7}
}
EUVIMED