Consumer-Grade Wearable Sensors for Classifying Pilot Workload and Stress During Real Flight Training: A Leave-One-Subject-Out Validation Study
Sensors · 06.06.2026 · 26 (12) · 3627
DOI: 10.3390/s26123627 ↗Kurz gefasst
Validierungsstudie in der Zeitschrift Sensors, online erschienen am 06.06.2026. Verfasst von Rongbing Xu und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Systems Design Engineering, University of Waterloo, Waterloo, ON N2L 3G1, Canada. Hauptthemen laut MEDLINE: Wearable Electronic Devices, Workload, Stress, Physiological. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 59 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Natural Sciences and Engineering Research Council of Canada.
Abstract (Originalsprache)
Consumer-grade wearable sensors may enable continuous monitoring of pilot workload and stress during flight training, yet most prior studies rely on simulators, raw-score labelling, and within-subject validation, limiting generalisability. This study evaluates whether electrodermal activity (EDA), electrocardiogram (ECG)-derived features, and wrist skin temperature, recorded from an Empatica Embrace Plus and a Polar H10 during real Cessna 172 flight training, can classify pilots’ task-relative workload and stress deviations. Thirty-five pilots completed four flight segments and rated workload and stress after each. Fold-safe two-way residual binary labels removed inter-pilot scale-use differences and task-level effects, and five classifiers were evaluated under leave-one-subject-out (LOSO) cross-validation with Benjamini–Hochberg FDR correction. Under LOSO, a Linear SVC on combined features classified stress (macro F1 = 0.607) and XGBoost on EDA classified workload (macro F1 = 0.598) significantly above chance (padj=0.033); both remained stable under nested cross-validation with an inner hyperparameter search (nested 0.606 and 0.561). A LightGBM model on EDA gave a numerically higher stress score (0.611) that did not survive nested validation. Subject-dependent within-subject validation produced higher apparent performance (macro F1 = 0.853 for stress and 0.791 for workload), but a stricter within-pilot analysis was unstable. These contrasts indicate that personalised classification may be feasible after calibration, whereas uncalibrated cross-pilot prediction in real flight remains modest, with post-flight debriefing the most plausible near-term application.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Systems Design Engineering, University of Waterloo, Waterloo, ON N2L 3G1, Canada.
- Waterloo Institute for Sustainable Aeronautics, University of Waterloo, Waterloo, ON N2L 3G1, Canada.
- Department of Kinesiology and Health Sciences, University of Waterloo, Waterloo, ON N2L 3G1, Canada.
- School of Optometry & Vision Science, University of Waterloo, Waterloo, ON N2L 3G1, Canada.
- Department of Geography and Environmental Management, University of Waterloo, Waterloo, ON N2L 3G1, Canada.
ORCID-Profile: Rongbing Xu, Shi Cao, Michael Barnett-Cowan, Suzanne Kearns
Förderung
- Natural Sciences and Engineering Research Council of Canada
Zitieren
APA
Xu, R., Cao, S., Barnett-Cowan, M., Irving, E., Niechwiej-Szwedo, E., & Kearns, S. (2026). Consumer-Grade Wearable Sensors for Classifying Pilot Workload and Stress During Real Flight Training: A Leave-One-Subject-Out Validation Study. Sensors, 26(12), 3627. https://doi.org/10.3390/s26123627
Vancouver
Xu R, Cao S, Barnett-Cowan M, Irving E, Niechwiej-Szwedo E, Kearns S. Consumer-Grade Wearable Sensors for Classifying Pilot Workload and Stress During Real Flight Training: A Leave-One-Subject-Out Validation Study. Sensors. 2026;26(12):3627. doi:10.3390/s26123627
BibTeX
@article{Xu2026,
author = {Xu, Rongbing and Cao, Shi and Barnett-Cowan, Michael and Irving, Elizabeth and Niechwiej-Szwedo, Ewa and Kearns, Suzanne},
title = {Consumer-Grade Wearable Sensors for Classifying Pilot Workload and Stress During Real Flight Training: A Leave-One-Subject-Out Validation Study},
journal = {Sensors},
year = {2026},
volume = {26},
number = {12},
pages = {3627},
doi = {10.3390/s26123627}
}
EUVIMED