A Wearable Device to Measure Bioimpedance and Electrodermal Activity
Sensors · 2026
DOI: 10.3390/s26185918 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, 2026. Verfasst von Jesús Ponce de León und 2 weiteren Autor:innen. Beteiligte Einrichtung: Escuela Universitaria Politécnica de La Almunia (EUPLA), University of Zaragoza, 50100 Zaragoza, Spain. Hauptthemen laut MEDLINE: Wearable Electronic Devices, Electric Impedance, Galvanic Skin Response. Die Arbeit nennt 40 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Ministry of Science and Information, Spanish Science, Innovation and University Ministry.
Abstract (Originalsprache)
Continuous non-invasive health monitoring requires wearable devices capable of capturing synchronized, multi-parametric physiological data without compromising user comfort or signal integrity. However, existing platforms often suffer from insufficient accuracy in complex modalities such bioimpedance. To address these limitations, this paper introduces the Multi-sensor Wearable Wristband Version 2.0 (MsW2-v2), an optimized, highly integrated platform designed for high-precision measurements. The methodology encompasses the hardware optimization of a previous prototype, integrating a low-leakage switching matrix and dual-bandwidth analog front ends to capture, in a quasi-simultaneous (time-multiplexed) manner, electrodermal activity (EDA) and bioimpedance (BiZ), as well as other physiological signals such as skin temperature, oxygen saturation, heart rate, and inertial motion. System validation was performed through rigorous laboratory calibration against reference impedances and subsequent in vivo testing on a human volunteer in an isolated room with no external stimuli whatsoever. The laboratory results indicated high-precision performance, with the mean absolute errors of the measurements being below 3 Ω in modulus and 0.2° in phase across a wide range of frequencies, from 1 kHz to 200 kHz. Preliminary in vivo benchmarks confirm the functionality of the device. These findings demonstrate that the MsW2-v2 successfully bridges the gap between high accuracy and wearable form factors, bringing us to the conclusion that this device could serve as a viable, scalable solution for real-time physiological measurements and biomedical signal monitoring.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Escuela Universitaria Politécnica de La Almunia (EUPLA), University of Zaragoza, 50100 Zaragoza, Spain.
- Escuela de Ingeniería y Arquitectura (EINA), University of Zaragoza, 50009 Zaragoza, Spain.
ORCID-Profile: Jesús Ponce de León, José Ramón Beltrán, David Asiain
Förderung
- Ministry of Science and Information
- Spanish Science, Innovation and University Ministry
Zitieren
APA
de León, J. P., Beltrán, J. R., & Asiain, D. (2026). A Wearable Device to Measure Bioimpedance and Electrodermal Activity. Sensors. https://doi.org/10.3390/s26185918
Vancouver
de León JP, Beltrán JR, Asiain D. A Wearable Device to Measure Bioimpedance and Electrodermal Activity. Sensors. 2026. doi:10.3390/s26185918
BibTeX
@article{deLen2026,
author = {de León, Jesús Ponce and Beltrán, José Ramón and Asiain, David},
title = {A Wearable Device to Measure Bioimpedance and Electrodermal Activity},
journal = {Sensors},
year = {2026},
doi = {10.3390/s26185918}
}
EUVIMED