EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Development of Wearable Heatstroke Warning System (HeatGuard): Design, Validation and Controlled-Environment Testing Among Triathletes

Kanchana Silawarawet iD, Chutipon Trirattananurak iD, Jirawat Muksuwan iD, Surasak Sangdao iD, Darawadee Panich iD, Sairag Saadprai iD

Sensors · 2026

DOI: 10.3390/s26082556 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Sensors, 2026. Verfasst von Kanchana Silawarawet und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Electrical and Computer Engineering, Faculty of Engineering, Thammasat School of Engineering, Thammasat University, Pathum Thani 12121,…. Hauptthemen laut MEDLINE: Wearable Electronic Devices, Heat Stroke, Athletes. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 49 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Center of Excellence in Creative Engineering Design and Development (CED2), Thammasat University.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Global warming and increasing heatwaves elevate the risk of exertional heat illnesses, particularly heatstroke, in endurance athletes and outdoor workers. This study developed and validated a wearable heatstroke warning system integrating physiological and environmental monitoring with a real-time web dashboard. The wrist- and finger-worn prototype comprised an ESP32 microcontroller and heart rate (MAX30101), skin temperature (MAX30205), ambient temperature and humidity (SHT31), and galvanic skin response (Grove-GSR v1.2) sensors with dual acoustic–visual alerts and WiFi transmission. Fifteen triathletes (18–39 years) completed 30 min of cycling in a climatic chamber: 0–15 min at 24 ± 1 °C, 70 ± 10% RH, and 16–30 min at 27 ± 1 °C, 90 ± 10% RH, with the workload rising from 40%HRmax by 10% every 10 min. Heart rate, estimated core temperature, ambient temperature, relative humidity, and GSR were recorded every 30 s and compared with standard devices using Spearman correlation (p = 0.01) and Wilcoxon signed-rank tests (p < 0.05). Heart rate, skin temperature (used a linear model to calculate core body temperature), ambient temperature, and humidity sensors showed fair–very good validity (r = 0.692, 0.995, 0.994, 0.952), while GSR was low (r = 0.298). No significant differences were observed for heart rate, skin temperature, and humidity (p > 0.05), but body temperature (p = 0.003) and GSR (p < 0.001) differed. The system showed promising validity for real-time heatstroke risk monitoring, with further refinement needed for skin temperature and GSR sensing.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Wearable Electronic DevicesHeat StrokeAthletesHumansHeart RateSkin TemperatureAdultAdolescentMonitoring, PhysiologicYoung AdultMaleHumidityFemaleGalvanic Skin Response

Stichwörter der Autor:innen

IoTenvironmental monitoringheat strainheatstroketriathleteswearable sensors

Autor:innen und Institutionen

  • Department of Electrical and Computer Engineering, Faculty of Engineering, Thammasat School of Engineering, Thammasat University, Pathum Thani 12121, Thailand.
  • School of Information, Computer, and Communication Technology (ICT), Sirindhorn International Institute of Technology, Pathum Thani 12121, Thailand.
  • Department of Sports Science and Sports Development, Faculty of Allied Health Sciences, Thammasat University, Pathum Thani 12121, Thailand.
  • Department of Medical Engineering, School of Engineering, Thammasat University, Pathum Thani 12121, Thailand.

ORCID-Profile: Kanchana Silawarawet, Chutipon Trirattananurak, Jirawat Muksuwan, Surasak Sangdao, Darawadee Panich, Sairag Saadprai

Förderung

  • Center of Excellence in Creative Engineering Design and Development (CED2), Thammasat University

Zitieren

APA

Silawarawet, K., Trirattananurak, C., Muksuwan, J., Sangdao, S., Panich, D., & Saadprai, S. (2026). Development of Wearable Heatstroke Warning System (HeatGuard): Design, Validation and Controlled-Environment Testing Among Triathletes. Sensors. https://doi.org/10.3390/s26082556

Vancouver

Silawarawet K, Trirattananurak C, Muksuwan J, Sangdao S, Panich D, Saadprai S. Development of Wearable Heatstroke Warning System (HeatGuard): Design, Validation and Controlled-Environment Testing Among Triathletes. Sensors. 2026. doi:10.3390/s26082556

BibTeX
@article{Silawarawet2026,
  author = {Silawarawet, Kanchana and Trirattananurak, Chutipon and Muksuwan, Jirawat and Sangdao, Surasak and Panich, Darawadee and Saadprai, Sairag},
  title = {Development of Wearable Heatstroke Warning System (HeatGuard): Design, Validation and Controlled-Environment Testing Among Triathletes},
  journal = {Sensors},
  year = {2026},
  doi = {10.3390/s26082556}
}
Kostenlos starten →