Fachartikel in der Zeitschrift Sensors, online erschienen am 28.05.2026. Verfasst von Enci Fan und 2 weiteren Autor:innen. Beteiligte Einrichtung: School of Computer and Artificial Intelligence, Beijing Technology and Business University, Beijing 102488, China. Die Arbeit nennt 34 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The accuracy of transit-time ultrasonic flow measurement depends strongly on stable time-of-flight (TOF) extraction. However, threshold-based TOF methods are susceptible to emission transients, structural ringing, and repeated threshold crossings, which may cause false triggering and timing fluctuations. This paper proposes a time-of-flight extraction method based on time-sequenced pulses for ultrasonic flow measurement using an FPGA-based time-to-digital converter (TDC). The method equalizes signal input paths, combines peripheral path switching with FPGA gating to achieve windowed valid-edge extraction, and exploits the temporal correspondence among consecutive excitation pulses to construct multiple TOF observations from matched pulse pairs, thereby improving extraction stability and timing efficiency. A complete FPGA-TDC ultrasonic flow measurement platform based on a Zynq UltraScale+ device was developed, and TDC linearity, timing precision, and flow calibration experiments were conducted. After code-density calibration, the four channels achieved RMS values of about 20 ps, and within a flow range of 0.7–3.6 m3/h, the relative error with respect to the reference flowmeter remained within ±0.6%, with repeatability errors below 0.3%. The platform operated stably under the present experimental conditions. These results demonstrate improved TOF extraction stability and overall flow measurement performance without complex full-waveform processing.

Schlagwörter

Stichwörter der Autor:innen

code-density calibrationfield programmable gate array (FPGA)time of flight (TOF)time-sequenced pulsestime-to-digital converter (TDC)ultrasonic flow measurement

Autor:innen und Institutionen

  • School of Computer and Artificial Intelligence, Beijing Technology and Business University, Beijing 102488, China.

Zitieren

APA

Fan, E., Xie, T., & Wu, F. (2026). A Time-of-Flight Extraction Method Based on Time-Sequenced Pulses for Ultrasonic Flow Measurement Using an FPGA-Based Time-to-Digital Converter. Sensors, 26(11), 3408. https://doi.org/10.3390/s26113408

Vancouver

Fan E, Xie T, Wu F. A Time-of-Flight Extraction Method Based on Time-Sequenced Pulses for Ultrasonic Flow Measurement Using an FPGA-Based Time-to-Digital Converter. Sensors. 2026;26(11):3408. doi:10.3390/s26113408

BibTeX
@article{Fan2026,
  author = {Fan, Enci and Xie, Tao and Wu, Fan},
  title = {A Time-of-Flight Extraction Method Based on Time-Sequenced Pulses for Ultrasonic Flow Measurement Using an FPGA-Based Time-to-Digital Converter},
  journal = {Sensors},
  year = {2026},
  volume = {26},
  number = {11},
  pages = {3408},
  doi = {10.3390/s26113408}
}
Kostenlos starten →