Fachartikel in der Zeitschrift Optics Express, online erschienen am 12.11.2026. Verfasst von Lijuan Xiang und 5 weiteren Autor:innen. Die Arbeit nennt 28 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Shenzhen Science and Technology Innovation Commission, Basic and Applied Basic Research Foundation of Guangdong Province.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

A time-dilation imaging camera with a temporal resolution of 5 ps was developed by integrating a 16 times dilation of the incoming optical signal and an 80 ps time-resolved microchannel plate (MCP)- gated detector. Temporal dilation was achieved by the photoelectron energy gradually decreasing over time and a 55 cm sufficiently long drift region. The relationship between the time-of-flight (TOF) of photoelectrons in the drift tube and their energy was investigated, and an ultrafast pulse waveform measurement technique based on the TOF was presented. The dilation pulse voltage is obtained using the TOF, and its slope is derived from the temporal resolution. The dilation pulse waveform was reconstructed using the electron energy and the measuring camera's temporal resolution, while the optical signal was synchronized to 20 different positions along the rising edge of the dilation pulse. The waveform measured by the time dilation imaging camera was consistent with that of the high-speed oscilloscope, with a discrepancy of less than 10%. The 5 ps temporal resolution corresponds to a reciprocal-time equivalent bandwidth of approximately 200 GHz. Within the low-space-charge regime, further optimization of the dilation pulse may provide a route toward higher temporal resolution and equivalent bandwidth.

Förderung

  • National Natural Science Foundation of China
  • Shenzhen Science and Technology Innovation Commission
  • Basic and Applied Basic Research Foundation of Guangdong Province
  • National Key Laboratory of Plasma Physics
  • Shenzhen Key Laboratory of Photonicsand Biophotonics

Zitieren

APA

Xiang, L., Chen, X., Deng, Z., Luo, Q., Du, Z., & Cai, H. (2026). Time-of-flight-based waveform measurement technique. Optics Express, 34(23), 44907. https://doi.org/10.1364/oe.609390

Vancouver

Xiang L, Chen X, Deng Z, Luo Q, Du Z, Cai H. Time-of-flight-based waveform measurement technique. Optics Express. 2026;34(23):44907. doi:10.1364/oe.609390

BibTeX
@article{Xiang2026,
  author = {Xiang, Lijuan and Chen, Xuan and Deng, Zhiying and Luo, Qiuyan and Du, Zhuoming and Cai, Houzhi},
  title = {Time-of-flight-based waveform measurement technique},
  journal = {Optics Express},
  year = {2026},
  volume = {34},
  number = {23},
  pages = {44907},
  doi = {10.1364/oe.609390}
}
Kostenlos starten →