Effect of Skin Pigmentation and Finger Choice on Accuracy of Oxygen Saturation Measurement in an IoT-Based Pulse Oximeter
Sensors · 2024
DOI: 10.3390/s24113301 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, 2024. Verfasst von Shyqyri Haxha und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Electronic Engineering, Royal Holloway, University of London, Egham TW20 0EX, UK. Hauptthemen laut MEDLINE: Oximetry, Skin Pigmentation, Fingers, Oxygen Saturation. Die Arbeit wurde bisher 12-mal zitiert (Crossref) und nennt 63 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Pulse oximeters are widely used in hospitals and homes for measurement of blood oxygen saturation level (SpO2) and heart rate (HR). Concern has been raised regarding a possible bias in obtaining pulse oximeter measurements from different fingertips and the potential effect of skin pigmentation (white, brown, and dark). In this study, we obtained 600 SpO2 measurements from 20 volunteers using three UK NHS-approved commercial pulse oximeters alongside our custom-developed sensor, and used the Munsell colour system (5YR and 7.5YR cards) to classify the participants’ skin pigmentation into three distinct categories (white, brown, and dark). The statistical analysis using ANOVA post hoc tests (Bonferroni correction), a Bland–Altman plot, and a correlation test were then carried out to determine if there was clinical significance in measuring the SpO2 from different fingertips and to highlight if skin pigmentation affects the accuracy of SpO2 measurement. The results indicate that although the three commercial pulse oximeters had different means and standard deviations, these differences had no clinical significance.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Electronic Engineering, Royal Holloway, University of London, Egham TW20 0EX, UK.
- East Kent Hospitals University NHS Foundation Trust, Canterbury CT2 7NT, UK.
- Hertfordshire Partnership University NHS Foundation Trust, Hatfield, St. Albans AL3 5TQ, UK.
ORCID-Profile: Shyqyri Haxha, Mian Ali, Vladimir Dyo
Zitieren
APA
Haxha, S., Nwibor, C., Ali, M., Sakel, M., Saunders, K., Dyo, V., & Nabakooza, S. (2024). Effect of Skin Pigmentation and Finger Choice on Accuracy of Oxygen Saturation Measurement in an IoT-Based Pulse Oximeter. Sensors. https://doi.org/10.3390/s24113301
Vancouver
Haxha S, Nwibor C, Ali M, Sakel M, Saunders K, Dyo V, et al. Effect of Skin Pigmentation and Finger Choice on Accuracy of Oxygen Saturation Measurement in an IoT-Based Pulse Oximeter. Sensors. 2024. doi:10.3390/s24113301
BibTeX
@article{Haxha2024,
author = {Haxha, Shyqyri and Nwibor, Chike and Ali, Mian and Sakel, Mohamed and Saunders, Karen and Dyo, Vladimir and Nabakooza, Shakira},
title = {Effect of Skin Pigmentation and Finger Choice on Accuracy of Oxygen Saturation Measurement in an IoT-Based Pulse Oximeter},
journal = {Sensors},
year = {2024},
doi = {10.3390/s24113301}
}
EUVIMED