EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Dynamic Transformer Based on Wavelet and Diffusion Prior Guidance for Cardiac Cine MRI Reconstruction

Bolun Zhao iD, Jun Lyu iD

Sensors · 01.05.2026 · 26 (9) · 2842

DOI: 10.3390/s26092842 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Sensors, online erschienen am 01.05.2026. Verfasst von Bolun Zhao und 1 weiteren Autor:innen. Beteiligte Einrichtung: School of Computer and Control Engineering, Yantai University, Yantai 264005, China. Hauptthemen laut MEDLINE: Magnetic Resonance Imaging, Cine, Image Processing, Computer-Assisted, Wavelet Analysis, Heart. Die Arbeit nennt 42 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Natural Science Foundation of China, Youth Innovation Science and Technology Support Program of Shandong Province, Youth Program of the Natural Science Foundation of Shandong Province.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Cardiac magnetic resonance imaging (CMR) is widely used for the diagnosis and functional assessment of cardiovascular diseases because of its noninvasive nature and excellent soft-tissue contrast. However, accelerated cine magnetic resonance imaging (cine MRI) acquisition usually relies on undersampling, which may lead to noise, aliasing artifacts, and detail loss in reconstructed images. To address this issue, we propose a wavelet-guided dynamic Transformer with diffusion priors for cardiac cine MRI reconstruction. Specifically, a diffusion model is introduced into a reduced latent feature space to generate high-frequency prior features with only 8 reverse sampling steps, thereby enhancing detail recovery while maintaining moderate computational cost. In addition, a wavelet-guided dynamic Transformer is designed to capture low-frequency structural information and temporal dependencies across adjacent frames. By combining wavelet-domain decomposition, diffusion priors, and dynamic spatiotemporal modeling, the proposed framework improves reconstruction quality while preserving temporal consistency. Experimental results on multiple cardiac cine MRI datasets show that the proposed method achieves superior reconstruction accuracy and temporal consistency over several competing approaches, while maintaining a favorable balance between computational efficiency and reconstruction performance. These findings indicate that the proposed framework is an effective and robust solution for accelerated cardiac cine MRI reconstruction.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Magnetic Resonance Imaging, CineImage Processing, Computer-AssistedWavelet AnalysisHeartHumansAlgorithms

Stichwörter der Autor:innen

MRI reconstructioncardiac cine MRIdiffusion modeltransformerwavelet transform

Autor:innen und Institutionen

  • School of Computer and Control Engineering, Yantai University, Yantai 264005, China.

ORCID-Profile: Bolun Zhao, Jun Lyu

Förderung

  • National Natural Science Foundation of China
  • Youth Innovation Science and Technology Support Program of Shandong Province
  • Youth Program of the Natural Science Foundation of Shandong Province
  • Yantai Basic Research Key Project

Zitieren

APA

Zhao, B., & Lyu, J. (2026). Dynamic Transformer Based on Wavelet and Diffusion Prior Guidance for Cardiac Cine MRI Reconstruction. Sensors, 26(9), 2842. https://doi.org/10.3390/s26092842

Vancouver

Zhao B, Lyu J. Dynamic Transformer Based on Wavelet and Diffusion Prior Guidance for Cardiac Cine MRI Reconstruction. Sensors. 2026;26(9):2842. doi:10.3390/s26092842

BibTeX
@article{Zhao2026,
  author = {Zhao, Bolun and Lyu, Jun},
  title = {Dynamic Transformer Based on Wavelet and Diffusion Prior Guidance for Cardiac Cine MRI Reconstruction},
  journal = {Sensors},
  year = {2026},
  volume = {26},
  number = {9},
  pages = {2842},
  doi = {10.3390/s26092842}
}
Kostenlos starten →