EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Prediction of Cataract Severity Using Slit Lamp Images from a Portable Smartphone Device: A Pilot Study

David Z Chen iD, Changshuo Liu iD, Junran Wu iD, Lei Zhu iD, Beng Chin Ooi

Sensors · 20.03.2026 · 26 (6) · 1954

DOI: 10.3390/s26061954 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Sensors, online erschienen am 20.03.2026. Verfasst von David Z Chen und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Ophthalmology, National University Hospital, Singapore 119024, Singapore. Hauptthemen laut MEDLINE: Smartphone, Cataract, Slit Lamp. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 47 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National University Health System, NUHS Summit Programme in Innovation, National University Hospital, Singapore.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Cataract diagnosis requires a comprehensive dilated examination by an ophthalmologist using a slit lamp; there is currently no effective means to objectively screen for cataracts in the community using portable devices without dilation. We hypothesized that it would be possible to predict cataract severity using deep learning on images taken using a portable smartphone-based slit lamp prototype, with and without dilation. In this prospective cross-sectional pilot study, slit lamp images were captured from eligible patients with cataracts in a tertiary clinic using a portable slit lamp prototype attached to a smartphone. The Pentacam nuclear staging score (PNS, Pentacam®, Oculus, Inc., Arlington, WA, USA) was taken from the dilated pupils and served as ground truth. A transformer prototypical network with the Swin transformer on the images was trained to assign the class label corresponding to the highest predicted probability. Heat maps were generated based on attribution masks to identify the anatomical areas of concern. A total of 1900 images from 198 eyes of 99 patients were captured. The average age was 65.3 ± 10.4 years (range, 41.0 to 88.0 years) and the average PNS score was 1.57 ± 0.81 (range, 0 to 4). The model achieved an average accuracy of 81.25% and 74.38% for undilated and dilated eyes, respectively. Heat map visualization using the integrated gradient method successfully identified the anatomical area of interest in certain images. This study suggests the possibility of estimating cataract density using a portable smartphone slit lamp device without dilation. Further work is under way to validate this technique in a larger and more diverse group of eyes with cataracts.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

SmartphoneCataractSlit LampHumansPilot ProjectsFemaleMiddle AgedAgedMaleAged, 80 and overAdultProspective StudiesCross-Sectional StudiesDeep Learning

Stichwörter der Autor:innen

cataractdeep learningremote monitoringscreeningteleophthalmology

Autor:innen und Institutionen

  • Department of Ophthalmology, National University Hospital, Singapore 119024, Singapore.
  • Centre for Innovational and Precision Eye Health, Yong Loo Lin School of Medicine, National University of Singapore, Singapore 119228, Singapore.
  • Department of Computer Science, National University of Singapore, Singapore 117417, Singapore.
  • School of Software Technology, Zhejiang University, Ningbo 315100, China.

ORCID-Profile: David Z Chen, Changshuo Liu, Junran Wu, Lei Zhu

Förderung

  • National University Health System
  • NUHS Summit Programme in Innovation
  • National University Hospital, Singapore

Zitieren

APA

Chen, D. Z., Liu, C., Wu, J., Zhu, L., & Ooi, B. C. (2026). Prediction of Cataract Severity Using Slit Lamp Images from a Portable Smartphone Device: A Pilot Study. Sensors, 26(6), 1954. https://doi.org/10.3390/s26061954

Vancouver

Chen DZ, Liu C, Wu J, Zhu L, Ooi BC. Prediction of Cataract Severity Using Slit Lamp Images from a Portable Smartphone Device: A Pilot Study. Sensors. 2026;26(6):1954. doi:10.3390/s26061954

BibTeX
@article{Chen2026,
  author = {Chen, David Z and Liu, Changshuo and Wu, Junran and Zhu, Lei and Ooi, Beng Chin},
  title = {Prediction of Cataract Severity Using Slit Lamp Images from a Portable Smartphone Device: A Pilot Study},
  journal = {Sensors},
  year = {2026},
  volume = {26},
  number = {6},
  pages = {1954},
  doi = {10.3390/s26061954}
}
Kostenlos starten →