EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC 4.0

Accurate detection and grading of pterygium through smartphone by a fusion training model

Yuwen Liu iD, Changsheng Xu, Shaopan Wang, Yuguang Chen, Xiang Lin, Shujia Guo, Zhaolin Liu, Yuqian Wang, Houjian Zhang, Yuli Guo, Caihong Huang, Huping Wu und 5 weitere

British Journal of Ophthalmology · 2024

DOI: 10.1136/bjo-2022-322552 ↗

Kurz gefasst

Fachartikel in der Zeitschrift British Journal of Ophthalmology, 2024. Verfasst von Yuwen Liu und 16 weiteren Autor:innen. Beteiligte Einrichtung: Eye Institute, Xiamen University, Xiamen, Fujian, China. Hauptthemen laut MEDLINE: Smartphone, Pterygium. Die Arbeit wurde bisher 18-mal zitiert (Crossref) und nennt 29 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: National Natural Science Foundation of China, the National Key R&D Program of China.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background/aims To improve the accuracy of pterygium screening and detection through smartphones, we established a fusion training model by blending a large number of slit-lamp image data with a small proportion of smartphone data.

Method

Two datasets were used, a slit-lamp image dataset containing 20 987 images and a smartphone-based image dataset containing 1094 images. The RFRC (Faster RCNN based on ResNet101) model for the detection model. The SRU-Net (U-Net based on SE-ResNeXt50) for the segmentation models. The open-cv algorithm measured the width, length and area of pterygium in the cornea.

Results

The detection model (trained by slit-lamp images) obtained the mean accuracy of 95.24%. The fusion segmentation model (trained by smartphone and slit-lamp images) achieved a microaverage F 1 score of 0.8981, sensitivity of 0.8709, specificity of 0.9668 and area under the curve (AUC) of 0.9295. Compared with the same group of patients’ smartphone and slit-lamp images, the fusion model performance in smartphone-based images (F 1 score of 0.9313, sensitivity of 0.9360, specificity of 0.9613, AUC of 0.9426, accuracy of 92.38%) is close to the model (trained by slit-lamp images) in slit-lamp images (F 1 score of 0.9448, sensitivity of 0.9165, specificity of 0.9689, AUC of 0.9569 and accuracy of 94.29%).

Conclusion

Our fusion model method got high pterygium detection and grading accuracy in insufficient smartphone data, and its performance is comparable to experienced ophthalmologists and works well in different smartphone brands.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

SmartphonePterygiumHumansCorneaSlit LampConjunctiva

Stichwörter der Autor:innen

conjunctivaimagingocular surfacetelemedicine

Autor:innen und Institutionen

  • Eye Institute, Xiamen University, Xiamen, Fujian, China.
  • Xiamen University National Institute for Data Science in Health and Medicine, Xiamen, Fujian, China.
  • Institute of Artificial Intelligence, Xiamen University, Xiamen, Fujian, China.
  • Department of Ophthalmology, Xiang'an Hospital of Xiamen University, Xiamen, China.
  • Department of Ophthalmology, The First Affiliated Hospital of University of South China, Hengyang, Hunan, China.
  • Eye Institute, Affiliated Xiamen Eye Center of Xiamen University, Xiamen, Fujian, China.

ORCID-Profile: Yuwen Liu

Förderung

  • National Natural Science Foundation of China
  • the National Key R&D Program of China

Zitieren

APA

Liu, Y., Xu, C., Wang, S., Chen, Y., Lin, X., Guo, S., Liu, Z., Wang, Y., Zhang, H., Guo, Y., Huang, C., Wu, H., Li, Y., Chen, Q., Hu, J., Luo, Z., & Liu, Z. (2024). Accurate detection and grading of pterygium through smartphone by a fusion training model. British Journal of Ophthalmology. https://doi.org/10.1136/bjo-2022-322552

Vancouver

Liu Y, Xu C, Wang S, Chen Y, Lin X, Guo S, et al. Accurate detection and grading of pterygium through smartphone by a fusion training model. British Journal of Ophthalmology. 2024. doi:10.1136/bjo-2022-322552

BibTeX
@article{Liu2024,
  author = {Liu, Yuwen and Xu, Changsheng and Wang, Shaopan and Chen, Yuguang and Lin, Xiang and Guo, Shujia and Liu, Zhaolin and Wang, Yuqian and Zhang, Houjian and Guo, Yuli and Huang, Caihong and Wu, Huping and Li, Ying and Chen, Qian and Hu, Jiaoyue and Luo, Zhiming and Liu, Zuguo},
  title = {Accurate detection and grading of pterygium through smartphone by a fusion training model},
  journal = {British Journal of Ophthalmology},
  year = {2024},
  doi = {10.1136/bjo-2022-322552}
}
Kostenlos starten →