EUVIMEDEUVIMED entdecken
BeobachtungsstudieOpen Access · CC BY-NC 4.0

Reliability and Accuracy of Smart Eye Camera in Determining Grading of Nuclear Cataract

Anak Agung Mas Putrawati Triningrat, Angelo Doniho, Wayan Gede Jayanegara, I Gde Raka Widiana, Siska Wigono, Ni Made Laksmi Utari, Eisuke Shimizu, Shintaro Nakayama, Thendy Foraldy

Korean Journal of Ophthalmology · 2025

DOI: 10.3341/kjo.2023.0131 ↗

Kurz gefasst

Beobachtungsstudie in der Zeitschrift Korean Journal of Ophthalmology, 2025. Verfasst von Anak Agung Mas Putrawati Triningrat und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Ophthalmology, Faculty of Medicine, Udayana University, Bali, Indonesia. Hauptthemen laut MEDLINE: Cataract, Photography, Smartphone. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 17 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

Cataracts are the cause of more than 50% of blindness in the world. Cataract is diagnosed using a slit lamp to evaluate the opacity of the lens. Slit lamps as the primary tools cataract are not available in primary care units. Smart Eye Camera (SEC) is a medical device placed on smartphone, capable of creating slit beam similar to conventional slit lamp. Previous studies have been conducted in Japan. We wanted to further compare ocular examination between SEC and conventional slit lamp with samples taken from UPTD Eye Clinic Ambon Vlissingen in Indonesia.

Methods

Observational analytical study with a cross-sectional study design. The research sample consisted of 67 people selected by consecutive sampling. All samples were examined for cataracts using a conventional slit lamp and SEC. To evaluate the accuracy of SEC, diagnosis of cataract was carried out by one observer based on slit-lamp images. The results of examinations were then compared with the examinations by two observers based on the SEC video, where the videos were read two times in a span of 1 week.

Results

Sixty-seven eye samples were taken with average age of 61.76 ± 5.83 years, visual acuity was 0.07 ± 0.12, intraocular pressure was 14.12 ± 2.06 mmHg, and SEC video duration was 4.15 ± 1.09 seconds. SEC intraobserver reliability has a κ of 0.795/0.818, SEC interobserver reliability has a κ of 0.795/0.817. SEC assessment accuracy for observer 1 has a κ of 0.606/0.681 and for observer 2 has a κ of 0.629/0.717, with the highest accuracy for cataract grade 3 (86.67% and 91.18%, respectively).

Conclusions

This study shows SEC has good consistency and reliability in assessing the degree of nuclear cataract compared to conventional slit lamp. This tool could be used for cataract screening in remote areas.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

CataractPhotographySmartphoneHumansCross-Sectional StudiesMaleReproducibility of ResultsFemaleMiddle AgedAgedSlit Lamp MicroscopyVisual AcuityEquipment Design

Stichwörter der Autor:innen

CataractNuclear cataractSlit lampSmart eye camera

Autor:innen und Institutionen

  • Department of Ophthalmology, Faculty of Medicine, Udayana University, Bali, Indonesia.
  • Department of Ophthalmology, Keio University School of Medicine, Tokyo, Japan.
  • OUI Inc, Tokyo, Japan.
  • Department of Ophthalmology, Faculty of Medicine and Health Science, Atma Jaya University, Jakarta, Indonesia.

Zitieren

APA

Triningrat, A. A. M. P., Doniho, A., Jayanegara, W. G., Widiana, I. G. R., Wigono, S., Utari, N. M. L., Shimizu, E., Nakayama, S., & Foraldy, T. (2025). Reliability and Accuracy of Smart Eye Camera in Determining Grading of Nuclear Cataract. Korean Journal of Ophthalmology. https://doi.org/10.3341/kjo.2023.0131

Vancouver

Triningrat AAMP, Doniho A, Jayanegara WG, Widiana IGR, Wigono S, Utari NML, et al. Reliability and Accuracy of Smart Eye Camera in Determining Grading of Nuclear Cataract. Korean Journal of Ophthalmology. 2025. doi:10.3341/kjo.2023.0131

BibTeX
@article{Triningrat2025,
  author = {Triningrat, Anak Agung Mas Putrawati and Doniho, Angelo and Jayanegara, Wayan Gede and Widiana, I Gde Raka and Wigono, Siska and Utari, Ni Made Laksmi and Shimizu, Eisuke and Nakayama, Shintaro and Foraldy, Thendy},
  title = {Reliability and Accuracy of Smart Eye Camera in Determining Grading of Nuclear Cataract},
  journal = {Korean Journal of Ophthalmology},
  year = {2025},
  doi = {10.3341/kjo.2023.0131}
}
Kostenlos starten →