Electromagnetic Performance Characterization and Circuit-Level Modeling of a Miniaturized Meander-Line Antenna for Implantable and Wearable RFID Applications
Sensors · 2026
DOI: 10.3390/s26061744 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, 2026. Verfasst von Waqas Ali und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Electrical Engineering, HITEC University, Taxila 47080, Pakistan. Hauptthemen laut MEDLINE: Wearable Electronic Devices, Radio Frequency Identification Device, Prostheses and Implants, Electromagnetic Phenomena. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 43 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
This paper proposes a small size meander-line patch antenna which is designed to have biomedical telemetry applications using the Industrial, Scientific and Medical (ISM) band from 2.40 to 2.48 GHz supported by the equivalent circuit model (ECM). Antenna miniaturization is realized by the effective use of several slot structures placed in the rectangular microstrip patch structure, in order to realize electrical length extension and reduce the physical size. The antenna has overall dimensions of 12 × 22 × 0.787 mm3 and is made on a low-loss Arlon AD 450 (εr = 4.50 and tanδ = 0.0035) dielectric substrate, which has the desired stable electrical behavior and, importantly, can be used in implantable environments. Experimental validation is done by implanting the fabricated prototype into a laboratory-manufactured tissue-mimicking phantom, and it showed good agreement with simulated results. The designed antenna has a peak gain of 1.29 dBi in free space and −24.99 dBi at a frequency of 2.45 GHz and a fractional impedance bandwidth of about 250 MHz, which will guarantee reliable operation in the face of diversity and fluctuation in the surrounding environment (biological tissues). Furthermore, specific absorption rate (SAR) analysis is carried out in order to comply with international safety standards with peak SAR values kept within the permissible level of 2 W/kg for 10 g averaging tissue. The results show that the proposed antenna provides a good trade-off between the reduction in size, radiation performance and safety to the patient, making it a good candidate for short-range in-body wireless communication, implantable medical devices, and biomedical monitoring systems.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Electrical Engineering, HITEC University, Taxila 47080, Pakistan.
- Department of Biomedical Engineering, HITEC University, Taxila 47080, Pakistan.
- Department of Telecommunication Engineering, University of Engineering and Technology, Taxila 47050, Pakistan.
- Department of Engineering, Gulf University for Science and Technology, Hawally 32093, Kuwait.
ORCID-Profile: Waqas Ali, N Nizam-Uddin, Ubaid Ullah, Muhammad Zahid, Sultan Shoaib
Zitieren
APA
Ali, W., Nizam-Uddin, N., Ullah, U., Zahid, M., & Shoaib, S. (2026). Electromagnetic Performance Characterization and Circuit-Level Modeling of a Miniaturized Meander-Line Antenna for Implantable and Wearable RFID Applications. Sensors. https://doi.org/10.3390/s26061744
Vancouver
Ali W, Nizam-Uddin N, Ullah U, Zahid M, Shoaib S. Electromagnetic Performance Characterization and Circuit-Level Modeling of a Miniaturized Meander-Line Antenna for Implantable and Wearable RFID Applications. Sensors. 2026. doi:10.3390/s26061744
BibTeX
@article{Ali2026,
author = {Ali, Waqas and Nizam-Uddin, N and Ullah, Ubaid and Zahid, Muhammad and Shoaib, Sultan},
title = {Electromagnetic Performance Characterization and Circuit-Level Modeling of a Miniaturized Meander-Line Antenna for Implantable and Wearable RFID Applications},
journal = {Sensors},
year = {2026},
doi = {10.3390/s26061744}
}
EUVIMED