Active Suppression of Differential Light Shift Drift in an Atom Gravimeter
Sensors · 04.03.2026 · 26 (5) · 1620
DOI: 10.3390/s26051620 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, online erschienen am 04.03.2026. Verfasst von Wei-Hao Xu und 11 weiteren Autor:innen. Beteiligte Einrichtung: Innovation Academy for Precision Measurement Science and Technology, Chinese Academy of Sciences, Wuhan 430071, China. Die Arbeit nennt 37 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: the Space Application System of China Manned Space Program, Quantum Science and Technology-National Science and Technology Major Project, the Hubei Provincial Science and Technology Major Project.
Abstract (Originalsprache)
Differential light shift (DLS) is an important error term that limits the atom interferometer’s measurement precision, especially for the case of the electro-optic modulator (EOM)-based scheme, where multiple laser sidebands exist, and their ratios are hard to control synchronously. This article carried out an experimental and theoretical study on this subject. By conducting long-term gravity measurement, we find that the gravity exhibits drifts of about 13.13 μGal, and is strongly correlated to the Raman laser’s sidebands. A model of the DLS-induced gravity error is established and a DLS compensation method is proposed to suppress the gravity drift to 2.54 μGal. Besides the compensation method, we propose a Dual-Sideband Ratio Locking scheme to more robustly eliminate the gravity measurement drift. By feeding back to both the EOM microwave power and the tapered amplifier’s temperature, this method locks both the ±1 order sideband to a stability level of 10−5, which corresponds to a gravity error of less than 0.1 μGal. Long-term gravity measurement is carried out after the locking method, showing a long-term stability of 1.6 μGal. The proposed methods will benefit the suppression of the DLS effect for high-precision atom interference measurement.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Innovation Academy for Precision Measurement Science and Technology, Chinese Academy of Sciences, Wuhan 430071, China.
- School of Physical Sciences, University of Chinese Academy of Sciences, Beijing 100049, China.
- Hefei National Laboratory, Hefei 230088, China.
- Wuhan Institute of Quantum Technology, Wuhan 430206, China.
ORCID-Profile: Wei-Hao Xu, Jin-Ting Li, Dan-Fang Zhang, Lin Zhou, Jin Wang
Förderung
- the Space Application System of China Manned Space Program
- Quantum Science and Technology-National Science and Technology Major Project
- the Hubei Provincial Science and Technology Major Project
- National Key R&D Program of China
- the National Natural Science Foundation of China
- the China Postdoctoral Science Foundation
- Space Application System of China Manned Space Program
- Hubei Provincial Science and Technology Major Project
Zitieren
APA
Xu, W. H., Chen, X., Li, J. T., Zhang, D. F., Wang, W. Z., Wei, J. Y., Zhong, J. Q., Tang, B., Zhou, L., Li, R. B., Wang, J., & Zhan, M. S. (2026). Active Suppression of Differential Light Shift Drift in an Atom Gravimeter. Sensors, 26(5), 1620. https://doi.org/10.3390/s26051620
Vancouver
Xu WH, Chen X, Li JT, Zhang DF, Wang WZ, Wei JY, et al. Active Suppression of Differential Light Shift Drift in an Atom Gravimeter. Sensors. 2026;26(5):1620. doi:10.3390/s26051620
BibTeX
@article{Xu2026,
author = {Xu, Wei-Hao and Chen, Xi and Li, Jin-Ting and Zhang, Dan-Fang and Wang, Wen-Zhang and Wei, Jia-Yi and Zhong, Jia-Qi and Tang, Biao and Zhou, Lin and Li, Run-Bing and Wang, Jin and Zhan, Min-Sheng},
title = {Active Suppression of Differential Light Shift Drift in an Atom Gravimeter},
journal = {Sensors},
year = {2026},
volume = {26},
number = {5},
pages = {1620},
doi = {10.3390/s26051620}
}