EUVIMEDEUVIMED entdecken
Crossref

Accurate Evaluation of the Scale Factor for a gPhone Relative Gravimeter With a Stable Cold Atom Gravimeter

Kainan Wang, Liming Wu, Bing Cheng, Xiaoyu Niu, Wenwen Yuan, Xiaochun Guo, Can Zhang, Yin Zhou, Kanxing Weng, Yufei Han, Bin Wu, Qiang Lin

IEEE Sensors Journal · 01.09.2025 · 25 (17) · 32326-32336

DOI: 10.1109/jsen.2025.3589769 ↗

Kurz gefasst

Fachartikel in der Zeitschrift IEEE Sensors Journal, erschienen am 01.09.2025. Verfasst von Kainan Wang und 11 weiteren Autor:innen. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 43 Literaturangaben. Gefördert von: the National Key Research and Development Program under Grant, Foundation for Innovative Research Groups of the National Natural Science Foundation of China.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Relative gravimeters are widely used for monitoring the time-variable gravity signals, which are important for the investigation of various geophysical phenomena. Moreover, it is crucial to evaluate accurately the scale factors of the relative gravimeter, as any variations or uncertainties in the scale factor can lead to deviations from true gravity values, directly affecting measurement accuracy. In this article, we present a home-made cold atom gravimeter (CAG) named an atom gravimeter developed by the research team at Zhejiang University of Technology Model (ZAG) with high accuracy and stability, demonstrating its suitability for the precise calibration of relative gravimeters. A 64-day simultaneous and co-located observation with the ZAG and a gPhone relative gravimeter was conducted at the Beijing National Earth Observatory (NEOBJI) for evaluating the scale factor of the relative gravimeter. To address the long-term drift of the gPhone, both polynomial regression and Kalman filtering methods were applied before the scale factor was estimated. The estimated scale factor is 1.03017, with a relative evaluation precision of approximately 0.30‰, determined by using the Kalman filter based on the gravity observation results from the ZAG as a reference. Additionally, the standard deviation of the residual signals over the 64-day gravity observation was calculated, yielding a value of $1.85~\mu $ Gal. The results outperform the commonly used method of polynomial regression. These findings provide valuable insights for the high-precision calibration of relative gravimeters and improving the quality of long-term gravity observation data.

Förderung

  • the National Key Research and Development Program under Grant
  • Foundation for Innovative Research Groups of the National Natural Science Foundation of China

Zitieren

APA

Wang, K., Wu, L., Cheng, B., Niu, X., Yuan, W., Guo, X., Zhang, C., Zhou, Y., Weng, K., Han, Y., Wu, B., & Lin, Q. (2025). Accurate Evaluation of the Scale Factor for a gPhone Relative Gravimeter With a Stable Cold Atom Gravimeter. IEEE Sensors Journal, 25(17), 32326-32336. https://doi.org/10.1109/jsen.2025.3589769

Vancouver

Wang K, Wu L, Cheng B, Niu X, Yuan W, Guo X, et al. Accurate Evaluation of the Scale Factor for a gPhone Relative Gravimeter With a Stable Cold Atom Gravimeter. IEEE Sensors Journal. 2025;25(17):32326-32336. doi:10.1109/jsen.2025.3589769

BibTeX
@article{Wang2025,
  author = {Wang, Kainan and Wu, Liming and Cheng, Bing and Niu, Xiaoyu and Yuan, Wenwen and Guo, Xiaochun and Zhang, Can and Zhou, Yin and Weng, Kanxing and Han, Yufei and Wu, Bin and Lin, Qiang},
  title = {Accurate Evaluation of the Scale Factor for a gPhone Relative Gravimeter With a Stable Cold Atom Gravimeter},
  journal = {IEEE Sensors Journal},
  year = {2025},
  volume = {25},
  number = {17},
  pages = {32326--32336},
  doi = {10.1109/jsen.2025.3589769}
}
Kostenlos starten →