Active vibration isolation control method for cold atom gravimeter based on output delay observer
Journal of Vibroengineering · 16.11.2026
DOI: 10.21595/jve.2026.26323 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Vibroengineering, online erschienen am 16.11.2026. Verfasst von Dongyun Luo und 3 weiteren Autor:innen. Die Arbeit nennt 30 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Cold atom gravimeters are high-precision instruments for measuring gravitational acceleration; however, their accuracy is highly susceptible to ground-vibration disturbances, especially in dynamic environments. Effective suppression of vibration-induced noise is therefore essential for improving the performance of such systems. This study aims to develop an active vibration-isolation method that compensates for delayed output measurements and suppresses vibration-induced displacement, velocity, and atom-interference phase noise in cold atom gravimeters. A dynamic state-space model of the active vibration isolation platform was established by considering the passive isolation structure, voice-coil actuator, ground-vibration disturbance, and output delay. An output delay observer (ODO) was designed to estimate the platform displacement and velocity and was integrated with a proportional-derivative controller to generate the active feedback force. The stability of the complete observer-controller system was analyzed using a composite Lyapunov function. Simulations were conducted under sinusoidal excitations from 0.1 to 10 Hz, band-limited Gaussian white noise, and measured ground-vibration input. The proposed method was compared with proportional-integral-derivative and sliding mode control. The stability analysis showed that the closed-loop system is asymptotically stable under constant or slowly varying disturbances and uniformly ultimately bounded under bounded time-varying disturbances. The proposed method produced the smallest displacement and velocity responses under all investigated conditions. The residual vibration noise was 91.13 %-95.95 % lower than that obtained using proportional-integral-derivative control and 71.30 %-95.21 % lower than that obtained using sliding mode control. The phase-noise standard deviation was reduced to 7.05×10 -4 rad, representing reductions of 95.10 % and 84.95 % relative to the two comparison methods, respectively. The output delay-observer-based active vibration isolation method provides an effective solution for suppressing vibration disturbances in cold atom gravimeters. The proposed control strategy significantly improves measurement accuracy and offers strong potential for high-precision gravimeter measurements in dynamic environments.
Zitieren
APA
Luo, D., Luo, X., Long, S., & Deng, C. (2026). Active vibration isolation control method for cold atom gravimeter based on output delay observer. Journal of Vibroengineering. https://doi.org/10.21595/jve.2026.26323
Vancouver
Luo D, Luo X, Long S, Deng C. Active vibration isolation control method for cold atom gravimeter based on output delay observer. Journal of Vibroengineering. 2026. doi:10.21595/jve.2026.26323
BibTeX
@article{Luo2026,
author = {Luo, Dongyun and Luo, Xingyang and Long, Shili and Deng, Changshou},
title = {Active vibration isolation control method for cold atom gravimeter based on output delay observer},
journal = {Journal of Vibroengineering},
year = {2026},
doi = {10.21595/jve.2026.26323}
}
EUVIMED