Peak-Independent Cuffless Blood Pressure Monitoring Using a Smart Sock: The Role of Temporal Lag Modeling in Foot-Based PPG
Sensors · 2026
DOI: 10.3390/s26041269 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, 2026. Verfasst von Hamed Abdollahzadeh und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Industrial and Information Engineering and Economics, University of L'Aquila, 67100 L'Aquila, Italy. Hauptthemen laut MEDLINE: Photoplethysmography, Blood Pressure, Blood Pressure Determination, Foot. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 23 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Continuous blood pressure (BP) monitoring remains a major challenge in wearable healthcare systems, as conventional cuff-based sphygmomanometers are intermittent and unsuitable for long-term use. This study presents a Smart Sock platform for cuffless BP estimation using single-site photoplethysmography (PPG). Unlike approaches based on pulse transit time or fiducial point detection, the proposed framework relies on peak-independent features extracted from PPG and its first and second derivatives, capturing blood volume and hemodynamic dynamics in the lower limb. PPG signals from 60 participants were segmented into overlapping 30 s windows and processed through a unified preprocessing pipeline. A compact set of physiologically meaningful statistical and information-theoretic features was extracted from each window, and temporal lag modelling (5–15 s) was employed to encode short-term hemodynamic memory without explicit peak detection. Multiple regression models were assessed using leakage-safe cross-validation strategies. In a subject-independent diagnosis scenario, the system achieved errors of 8.60 mmHg for systolic BP and 6.42 mmHg for diastolic BP. In a monitoring scenario with single-point calibration, performance substantially improved, yielding mean absolute errors of 1.3–1.7 mmHg and R2 > 0.90. These results demonstrate that foot-based PPG, combined with peak-independent feature engineering and temporal context modeling, enables accurate and comfortable continuous personalized blood pressure monitoring after calibration, while subject-independent estimation remains more challenging.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Industrial and Information Engineering and Economics, University of L'Aquila, 67100 L'Aquila, Italy.
ORCID-Profile: Hamed Abdollahzadeh, Elisa Montaldi, Riccardo Olivieri, Paolo Esposito, Gianluca Barile, Giuseppe Ferri, Vincenzo Stornelli
Zitieren
APA
Abdollahzadeh, H., Montaldi, E., Olivieri, R., Esposito, P., Barile, G., Ferri, G., & Stornelli, V. (2026). Peak-Independent Cuffless Blood Pressure Monitoring Using a Smart Sock: The Role of Temporal Lag Modeling in Foot-Based PPG. Sensors. https://doi.org/10.3390/s26041269
Vancouver
Abdollahzadeh H, Montaldi E, Olivieri R, Esposito P, Barile G, Ferri G, et al. Peak-Independent Cuffless Blood Pressure Monitoring Using a Smart Sock: The Role of Temporal Lag Modeling in Foot-Based PPG. Sensors. 2026. doi:10.3390/s26041269
BibTeX
@article{Abdollahzadeh2026,
author = {Abdollahzadeh, Hamed and Montaldi, Elisa and Olivieri, Riccardo and Esposito, Paolo and Barile, Gianluca and Ferri, Giuseppe and Stornelli, Vincenzo},
title = {Peak-Independent Cuffless Blood Pressure Monitoring Using a Smart Sock: The Role of Temporal Lag Modeling in Foot-Based PPG},
journal = {Sensors},
year = {2026},
doi = {10.3390/s26041269}
}
EUVIMED