Fachartikel in der Zeitschrift Sensors, 2025. Verfasst von Khouloud Jomaa und 4 weiteren Autor:innen. Beteiligte Einrichtung: Electronics and Micro-Electronic Laboratory (LEµE), Bd de L'environnement, Monastir 5000, Tunisia. Hauptthemen laut MEDLINE: Microwaves, Biosensing Techniques, Glucose. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 79 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Non-invasive glucose monitoring remains a significant challenge in diabetes management, with existing approaches often limited by poor accuracy, high cost, or patient discomfort. Microwave-based biosensors offer a promising label-free alternative by exploiting the dielectric contrast between glucose and water. This paper presents a compact, dual-band concentric square-shaped split-ring resonator (SRR-type) biosensor fabricated on a low-cost FR-4 substrate for aqueous glucose detection. The sensor leverages electric field confinement in inter-ring gaps to transduce glucose-induced permittivity changes into measurable shifts in resonance frequency and reflection coefficient. Experimental results demonstrate a linear, monotonic response across the clinical range up to 250 mg/dL, with a frequency-domain sensitivity of 1.964 MHz/(mg/dL) and amplitude-domain sensitivity of 0.0332 dB/(mg/dL), achieving high coefficients of determination (R2 = 0.9956 and 0.9927, respectively). The design achieves a normalized size of 0.137 λg2, combining high sensitivity and compact size within a scalable platform. Operating in the UWB-adjacent band (2.76–3.25 GHz), the proposed biosensor provides a practical, reproducible, and PCB-compatible solution for next-generation label-free glucose monitoring.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Electronics and Micro-Electronic Laboratory (LEµE), Bd de L'environnement, Monastir 5000, Tunisia.
- RF2S Spectrum Solutions, 18 Street of the Faïencerie, 33300 Bordeaux, France.
- University Grenoble-Alpes, Grenoble-INP/LCIS, 26000 Valence, France.
- Higher Institute of Applied Sciences and Technology of Sousse, University of Sousse, Street Taher Ben Achour, Sousse 4003, Tunisia.
ORCID-Profile: Khouloud Jomaa, Sehmi Saad, Darine Kaddour, Pierre Lemaître-Auger, Hatem Garrab
Zitieren
APA
Jomaa, K., Saad, S., Kaddour, D., Lemaître-Auger, P., & Garrab, H. (2025). A Linear and High-Sensitivity Microwave Biosensor on a FR-4 Substrate for Aqueous Glucose Monitoring Using a Concentric Square-Shaped Split-Ring Resonator. Sensors. https://doi.org/10.3390/s26010131
Vancouver
Jomaa K, Saad S, Kaddour D, Lemaître-Auger P, Garrab H. A Linear and High-Sensitivity Microwave Biosensor on a FR-4 Substrate for Aqueous Glucose Monitoring Using a Concentric Square-Shaped Split-Ring Resonator. Sensors. 2025. doi:10.3390/s26010131
BibTeX
@article{Jomaa2025,
author = {Jomaa, Khouloud and Saad, Sehmi and Kaddour, Darine and Lemaître-Auger, Pierre and Garrab, Hatem},
title = {A Linear and High-Sensitivity Microwave Biosensor on a FR-4 Substrate for Aqueous Glucose Monitoring Using a Concentric Square-Shaped Split-Ring Resonator},
journal = {Sensors},
year = {2025},
doi = {10.3390/s26010131}
}
EUVIMED