Microfluidic Microwave Sensor Based on a Twisted Cross-Shaped Structure for Glucose Detection
Sensors · 2025
DOI: 10.3390/s25133974 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, 2025. Verfasst von Yun Ma und 6 weiteren Autor:innen. Beteiligte Einrichtung: School of Electronic Information Engineering, China West Normal University, Nanchong 637009, China. Hauptthemen laut MEDLINE: Microwaves, Glucose, Biosensing Techniques, Microfluidic Analytical Techniques. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 59 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Natural Science Foundation of China, the Doctoral research start-up project of China West Normal University, the Youth Fund Project of Sichuan Province China.
Abstract (Originalsprache)
Microwave sensors have shown significant potential for glucose detection. However, temperature fluctuations have the drawback of interfering with the measurement accuracy of microwave sensors. In this work, a novel microwave sensor based on the twisted cross-shaped structure for glucose detection is designed, applying a microfluidic device for precise temperature control. The operating frequency of this sensor is 6900 MHz, and its sensitivity is 0.54%. The experimental results show that under the constant temperature, due to an increase of 0.2 mol/L in glucose concentration, the resonance point frequency of the scattering parameter (S21) is shifted approximately 10 to 60 MHz. With the increase in glucose concentration, the resonance amplitude of the S21 increases, while the frequency shift decreases. At 9 °C, when the glucose concentration is within the range of 0.05 to 0.2 mol/L, the frequency shift is about 50 MHz. Under the constant glucose concentration, due to an increase of 10 °C in temperature, the resonance point frequency of the scattering parameter (S21) is shifted approximately 10 to 130 MHz. At the 0.01 mol/L glucose concentration, when the temperature is within the range of 9 to 15 °C, the frequency shift is about 130 MHz. This work provides a novel approach for glucose monitoring and also offers experimental support for the application of microwave sensors in biomedicine.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- School of Electronic Information Engineering, China West Normal University, Nanchong 637009, China.
ORCID-Profile: Yun Ma, Chaojun Chen, Dezhi Gou
Förderung
- National Natural Science Foundation of China
- the Doctoral research start-up project of China West Normal University
- the Youth Fund Project of Sichuan Province China
- the Innovation Team of China West Normal University
- China West Normal University
- Youth Fund Project of Sichuan Province China
Zitieren
APA
Ma, Y., Zhao, C., Chen, C., Guo, Q., Zhu, J., Gou, D., & Liu, C. (2025). Microfluidic Microwave Sensor Based on a Twisted Cross-Shaped Structure for Glucose Detection. Sensors. https://doi.org/10.3390/s25133974
Vancouver
Ma Y, Zhao C, Chen C, Guo Q, Zhu J, Gou D, et al. Microfluidic Microwave Sensor Based on a Twisted Cross-Shaped Structure for Glucose Detection. Sensors. 2025. doi:10.3390/s25133974
BibTeX
@article{Ma2025,
author = {Ma, Yun and Zhao, Chenxi and Chen, Chaojun and Guo, Quanlin and Zhu, Junxi and Gou, Dezhi and Liu, Chuan},
title = {Microfluidic Microwave Sensor Based on a Twisted Cross-Shaped Structure for Glucose Detection},
journal = {Sensors},
year = {2025},
doi = {10.3390/s25133974}
}
EUVIMED