Fachartikel in der Zeitschrift Sensors, online erschienen am 25.08.2025. Verfasst von Juntong Cui und 2 weiteren Autor:innen. Beteiligte Einrichtung: School of Integrated Circuits, Jiangnan University, Wuxi 214122, China. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 28 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Natural Science Foundation of China, Postdoctoral Science Foundation of China, Postdoctoral Research Foundation of Zhejiang Province.
Abstract (Originalsprache)
Miniaturized pressure sensors fabricated via micro-electro-mechanical systems (MEMSs) technology are ubiquitous in modern applications. However, the massively produced MEMS pressure sensors, prior to being practically used, need to be calibrated one by one to eliminate or minimize nonlinearity and zero drift. This paper presents a systematic design for the testing and calibration process of MEMS-based absolute pressure sensors. Firstly, a numerical analysis is carried out using finite element method (FEM) simulation, which verifies the accuracy of the temperature control of the physical calibration system. The simulation results reveal a slight non-uniformity of temperature distribution, which is then taken into consideration in the calibration algorithm. Secondly, deploying a home-made calibration system, the MEMS pressure sensors are tested automatically and rapidly. The experimental results show that each batch, which consists of nine sensors, can be calibrated in 80 min. The linearity and temperature coefficient (TC) of the pressure sensors are reduced from 46.5% full-scale (FS) and −1.35 × 10−4 V·K−1 to 1.5% FS and −8.8 × 10−7 V·K−1.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- School of Integrated Circuits, Jiangnan University, Wuxi 214122, China.
ORCID-Profile: Juntong Cui, Yanfeng Jiang
Förderung
- National Natural Science Foundation of China
- Postdoctoral Science Foundation of China
- Postdoctoral Research Foundation of Zhejiang Province
- National Key R&D Program of China
Zitieren
APA
Cui, J., Zhang, S., & Jiang, Y. (2025). Design of a Rapid and Accurate Calibration System for Pressure Sensors with Minimized Temperature Variation. Sensors, 25(17), 5288. https://doi.org/10.3390/s25175288
Vancouver
Cui J, Zhang S, Jiang Y. Design of a Rapid and Accurate Calibration System for Pressure Sensors with Minimized Temperature Variation. Sensors. 2025;25(17):5288. doi:10.3390/s25175288
BibTeX
@article{Cui2025,
author = {Cui, Juntong and Zhang, Shubin and Jiang, Yanfeng},
title = {Design of a Rapid and Accurate Calibration System for Pressure Sensors with Minimized Temperature Variation},
journal = {Sensors},
year = {2025},
volume = {25},
number = {17},
pages = {5288},
doi = {10.3390/s25175288}
}
EUVIMED