EUVIMEDEUVIMED entdecken
Crossref

Calibration of Pressure Sensors for Ocean-Bottom Seismology

Spahr C. Webb, Hatsuki Yamauchi, Theodore A. Koczynski, Walter Masterson, Peter Liljegren

Bulletin of the Seismological Society of America · 01.06.2026 · 116 (3) · 860-883

DOI: 10.1785/0120250278 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Bulletin of the Seismological Society of America, online erschienen am 26.03.2026. Verfasst von Spahr C. Webb und 4 weiteren Autor:innen. Die Arbeit nennt 39 Literaturangaben.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Three types of pressure sensors are used for seismic and oceanographic observations in seafloor instruments: the hydrophone, the differential pressure gauge (DPG), and the high sampling rate absolute pressure gauge (APG). There has not been a good way to accurately calibrate these sensors across the entire frequency range of importance to seismologists (5 mHz to 200 Hz). We constructed a system to introduce time-varying pressure signals into a pressure test chamber to accurately calibrate each sensor at seafloor pressures. The gain decreased by more than 40% and the capacitance of the Hitech HTI-U-90 hydrophone by 25% with depth from 0 to 5000 m effecting the response. The DPG gain increases linearly with log frequency by 3% per decade from 0.1 mHz to about 10 Hz due to the viscoelastic deformation of the o-rings in the overpressure relief valves. The DPG gain changes with temperature and pressure. The time constant for the DPG high-pass capillary leak mechanical filter increases with depth (pressure) and decreases with temperature, increasing from about 100 s at 10 m and 20°C to about 300 s at 5000 m and 2°C. Future work will be required to determine the upper frequency limit of the response of the DPG. Our results show good results to 125 Hz, and suggest the DPG could fully replace hydrophones for many seismic observations at the seafloor. The APG has a simple, stable response ideal for observing large dynamic range signals, but the APG inlet piping acts as a low-pass filter with a corner frequency that may depend on pressure and temperature.

Zitieren

APA

Webb, S. C., Yamauchi, H., Koczynski, T. A., Masterson, W., & Liljegren, P. (2026). Calibration of Pressure Sensors for Ocean-Bottom Seismology. Bulletin of the Seismological Society of America, 116(3), 860-883. https://doi.org/10.1785/0120250278

Vancouver

Webb SC, Yamauchi H, Koczynski TA, Masterson W, Liljegren P. Calibration of Pressure Sensors for Ocean-Bottom Seismology. Bulletin of the Seismological Society of America. 2026;116(3):860-883. doi:10.1785/0120250278

BibTeX
@article{Webb2026,
  author = {Webb, Spahr C. and Yamauchi, Hatsuki and Koczynski, Theodore A. and Masterson, Walter and Liljegren, Peter},
  title = {Calibration of Pressure Sensors for Ocean-Bottom Seismology},
  journal = {Bulletin of the Seismological Society of America},
  year = {2026},
  volume = {116},
  number = {3},
  pages = {860--883},
  doi = {10.1785/0120250278}
}
Kostenlos starten →