Evaluating the Accuracy and Repeatability of Mobile 3D Imaging Applications for Breast Phantom Reconstruction
Sensors · 2025
DOI: 10.3390/s25154596 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, 2025. Verfasst von Elena Botti und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Electronics and Informatics (ETRO), Vrije Universiteit Brussel (VUB), Pleinlaan 2, B-1050 Brussels, Belgium. Hauptthemen laut MEDLINE: Imaging, Three-Dimensional, Phantoms, Imaging, Breast, Mammaplasty. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 29 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Three-dimensional imaging technologies are increasingly used in breast reconstructive and plastic surgery due to their potential for efficient and accurate preoperative assessment and planning. This study systematically evaluates the accuracy and consistency of six commercially available 3D scanning applications (apps)—Structure Sensor, 3D Scanner App, Heges, Polycam, SureScan, and Kiri—in reconstructing the female torso. To avoid variability introduced by human subjects, a silicone breast mannequin model was scanned, with fiducial markers placed at known anatomical landmarks. Manual distance measurements were obtained using calipers by two independent evaluators and compared to digital measurements extracted from 3D reconstructions in Blender software. Each scan was repeated six times per application to ensure reliability. SureScan demonstrated the lowest mean error (2.9 mm), followed by Structure Sensor (3.0 mm), Heges (3.6 mm), 3D Scanner App (4.4 mm), Kiri (5.0 mm), and Polycam (21.4 mm), which showed the highest error and variability. Even the app using an external depth sensor (Structure Sensor) showed no statistically significant accuracy advantage over those using only the iPad’s built-in camera (except for Polycam), underscoring that software is the primary driver of performance, not hardware (alone). This work provides practical insights for selecting mobile 3D scanning tools in clinical workflows and highlights key limitations, such as scaling errors and alignment artifacts. Future work should include patient-based validation and explore deep learning to enhance reconstruction quality. Ultimately, this study lays the foundation for more accessible and cost-effective 3D imaging in surgical practice, showing that smartphone-based tools can produce clinically useful scans.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Electronics and Informatics (ETRO), Vrije Universiteit Brussel (VUB), Pleinlaan 2, B-1050 Brussels, Belgium.
- IMEC, Kapeldreef 75, B-3001 Leuven, Belgium.
- Robotics & Multibody Mechanics (R&MM) Research Group, Vrije Universiteit Brussel, B-1050 Brussels, Belgium.
- Flanders Make, B-1050 Brussels, Belgium.
- Department of Plastic, Reconstructive and Aesthetic Surgery, Brussels University Hospital (UZ Brussel), Vrije Universiteit Brussel (VUB), Laarbeeklaan 101, B-1090 Brussels, Belgium.
ORCID-Profile: Elena Botti, Bart Jansen, Felipe Ballen-Moreno, Ayush Kapila, Redona Brahimetaj
Zitieren
APA
Botti, E., Jansen, B., Ballen-Moreno, F., Kapila, A., & Brahimetaj, R. (2025). Evaluating the Accuracy and Repeatability of Mobile 3D Imaging Applications for Breast Phantom Reconstruction. Sensors. https://doi.org/10.3390/s25154596
Vancouver
Botti E, Jansen B, Ballen-Moreno F, Kapila A, Brahimetaj R. Evaluating the Accuracy and Repeatability of Mobile 3D Imaging Applications for Breast Phantom Reconstruction. Sensors. 2025. doi:10.3390/s25154596
BibTeX
@article{Botti2025,
author = {Botti, Elena and Jansen, Bart and Ballen-Moreno, Felipe and Kapila, Ayush and Brahimetaj, Redona},
title = {Evaluating the Accuracy and Repeatability of Mobile 3D Imaging Applications for Breast Phantom Reconstruction},
journal = {Sensors},
year = {2025},
doi = {10.3390/s25154596}
}
EUVIMED