EUVIMEDEUVIMED entdecken
ValidierungsstudieOpen Access · CC BY 4.0

Development and validation of a photogrammetry-based preoperative method (BREAST-E) for quantitative breast morphometric analysis and volume estimation of breast in reconstructive surgery

Mee Hoong See iD, Kwan Hoong Ng iD, Teng Aik Ong iD, Lai Kuan Wong iD, Lee Lee Lai, Sheng Pu Teo, Jing Hui Ng, Jia Min Tneoh iD, Mahmoud Danaee iD

PLOS One · 28.07.2026 · 21 (7) · e0353970

DOI: 10.1371/journal.pone.0353970 ↗

Kurz gefasst

Validierungsstudie in der Zeitschrift PLOS One, online erschienen am 28.07.2026. Verfasst von Mee Hoong See und 8 weiteren Autor:innen. Beteiligte Einrichtung: Breast and Endocrine Surgery Unit, Department of Surgery, Faculty of Medicine, Universiti Malaya, Kuala Lumpur, Malaysia. Hauptthemen laut MEDLINE: Photogrammetry, Breast, Mammaplasty. Die Arbeit nennt 39 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: UMSC CARE, MMU Internal research grant.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

The demand for reproducible, reliable, and cost-effective tools regarding preoperative breast surgery planning is significant in low- and middle-income countries (LMICs) due to limited advanced imaging access, insufficient standardisation, and high cost. This study developed the BREAST-E technique for accurate and standardised breast volume analysis. Methodology A photogrammetry method assessed four ptosis levels: (i) no-ptosis, (ii) mild, [Watterson PA, et al. Plastic and Reconstructive Surgery. 1995;95:1185–94] moderate, and (iv) severe. Key parameters included marker counts (20, 40, and 60), photo angles (10°, 20°, and 30°), and offset adjustments (−0.01, 0, and +0.01). Two-dimensional (2D) images were converted into 3D models via Photomodeler for volume estimation. Clinical validation involved 12 patients (13 breasts) undergoing mastectomy, comparing estimated breast volumes to mastectomy specimens. The primary endpoint was accuracy of volume estimation compared with mastectomy specimen volume, while secondary endpoints included reliability, agreement, and workflow feasibility.

Results

The BREAST-E technique yielded promising accuracy [Pearson correlation coefficient ( R ) = 0.899 and mean absolute error (MAE) = 98.12 mL] and encouraging reliability (ICC = 0.995–0.996) across ptosis levels. Bland-Altman analysis indicated negligible bias, while Cronbach’s alpha (reaching 0.994) demonstrated robust internal consistency. Clinical validation also implied strong performance ( R = 0.789, MAE = 104.69 mL, and mean error = −27.00 mL). Consequently, no-ptosis presented the highest reliability (ICC = 0.81 and Cronbach’s alpha = 0.92) with minimal bias, whereas moderate and severe ptosis levels demonstrated greater variability.

Conclusion

This study successfully indicated that a reproducible, accessible, and cost-effective method for analysing breast volume was accomplished through the proposed BREAST-E technique for LMICs.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

PhotogrammetryBreastMammaplastyHumansFemaleAdultReproducibility of ResultsMiddle AgedOrgan SizeMastectomyImaging, Three-Dimensional

Autor:innen und Institutionen

  • Breast and Endocrine Surgery Unit, Department of Surgery, Faculty of Medicine, Universiti Malaya, Kuala Lumpur, Malaysia.
  • Surgery Department, Faculty of Medicine, Universiti Malaya, Kuala Lumpur, Malaysia.
  • Department Biomedical Imaging, Faculty of Medicine, Universiti Malaya, Kuala Lumpur, Malaysia.
  • Faculty of Medicine and Health Sciences, UCSI University, Springhill, Negeri Sembilan, Malaysia.
  • Faculty of Computing and Informatics, Multimedia University, Cyberjaya, Selangor, Malaysia.
  • Department of Social and Preventive Medicine, Faculty of Medicine, Universiti Malaya, Kuala Lumpur, Malaysia.

ORCID-Profile: Mee Hoong See, Kwan Hoong Ng, Teng Aik Ong, Lai Kuan Wong, Jia Min Tneoh, Mahmoud Danaee

Förderung

  • UMSC CARE
  • MMU Internal research grant

Zitieren

APA

See, M. H., Ng, K. H., Ong, T. A., Wong, L. K., Lai, L. L., Teo, S. P., Ng, J. H., Tneoh, J. M., & Danaee, M. (2026). Development and validation of a photogrammetry-based preoperative method (BREAST-E) for quantitative breast morphometric analysis and volume estimation of breast in reconstructive surgery. PLOS One, 21(7), e0353970. https://doi.org/10.1371/journal.pone.0353970

Vancouver

See MH, Ng KH, Ong TA, Wong LK, Lai LL, Teo SP, et al. Development and validation of a photogrammetry-based preoperative method (BREAST-E) for quantitative breast morphometric analysis and volume estimation of breast in reconstructive surgery. PLOS One. 2026;21(7):e0353970. doi:10.1371/journal.pone.0353970

BibTeX
@article{See2026,
  author = {See, Mee Hoong and Ng, Kwan Hoong and Ong, Teng Aik and Wong, Lai Kuan and Lai, Lee Lee and Teo, Sheng Pu and Ng, Jing Hui and Tneoh, Jia Min and Danaee, Mahmoud},
  title = {Development and validation of a photogrammetry-based preoperative method (BREAST-E) for quantitative breast morphometric analysis and volume estimation of breast in reconstructive surgery},
  journal = {PLOS One},
  year = {2026},
  volume = {21},
  number = {7},
  pages = {e0353970},
  doi = {10.1371/journal.pone.0353970}
}
Kostenlos starten →