EUVIMEDEUVIMED entdecken
Validierungsstudie

3D Breast Scanning in Plastic Surgery Utilizing Free iPhone LiDAR Application: Evaluation, Potential, and Limitations

Ioannis Kyriazidis iD, Juan Enrique Berner iD, Karl Waked, Moustapha Hamdi iD

Aesthetic Surgery Journal · 2025

DOI: 10.1093/asj/sjae251 ↗

Kurz gefasst

Validierungsstudie in der Zeitschrift Aesthetic Surgery Journal, 2025. Verfasst von Ioannis Kyriazidis und 3 weiteren Autor:innen. Hauptthemen laut MEDLINE: Imaging, Three-Dimensional, Breast, Mobile Applications, Smartphone. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 15 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Three-dimensional (3D) imaging enhances surgical planning and documentation in plastic surgery, but high costs limit accessibility. Mobile light detection and ranging (LiDAR) technology offers a potential cost-effective alternative.

Objectives

The objective of this research was to evaluate the accuracy and clinical utility of iPhone-based LiDAR scanning for breast measurements compared to traditional methods, and to establish standardized protocols for clinical implementation.

Methods

In this prospective validation study, 25 consecutive patients (mean age: 44 years; range: 32-64 years; mean BMI: 23.2 kg/m2) undergoing breast procedures were evaluated with the “3D Scanner App” on the iPhone 15 Pro (Apple Inc., Cupertino, CA). Three standardized measurements (sternal notch-to-nipple, nipple-to-midline, nipple-to-inframammary fold) of LiDAR and manual techniques were compared. Technical error of measurement (TEM) and relative TEM (rTEM) were calculated. Interrater reliability, learning curve assessment, and cost-effectiveness analysis were performed.

Results

LiDAR measurements showed very good accuracy for sternal notch-to-nipple (rTEM 1.43%, 95% CI: 1.21-1.65) and nipple-to-midline (rTEM 2.83%, 95% CI: 3.12-3.78) distances. Nipple-to-inframammary fold measurements showed poor accuracy (rTEM 13.05%, 95% CI: 8.21-9.39). Interrater reliability was excellent (ICC = 0.92). Learning curve analysis demonstrated measurement stability after 5 cases. Cost analysis revealed 97.8% reduction in initial investment compared to commercial 3D imaging systems.

Conclusions

Mobile LiDAR offers a cost-effective tool for breast surgery planning and documentation. While measurements like sternum-to-nipple and nipple-to-midline are highly accurate, the relatively poor accuracy of nipple-to-IMF highlights limitations with complex curves. As this technology continues to evolve, further improvements in accuracy are anticipated, expanding its role in clinical use. Level of Evidence: 4 (Therapeutic)

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Imaging, Three-DimensionalBreastMobile ApplicationsSmartphoneMammaplastyHumansFemaleAdultProspective StudiesMiddle AgedCost-Benefit AnalysisReproducibility of Results

Autor:innen und Institutionen

ORCID-Profile: Ioannis Kyriazidis, Juan Enrique Berner, Moustapha Hamdi

Zitieren

APA

Kyriazidis, I., Berner, J. E., Waked, K., & Hamdi, M. (2025). 3D Breast Scanning in Plastic Surgery Utilizing Free iPhone LiDAR Application: Evaluation, Potential, and Limitations. Aesthetic Surgery Journal. https://doi.org/10.1093/asj/sjae251

Vancouver

Kyriazidis I, Berner JE, Waked K, Hamdi M. 3D Breast Scanning in Plastic Surgery Utilizing Free iPhone LiDAR Application: Evaluation, Potential, and Limitations. Aesthetic Surgery Journal. 2025. doi:10.1093/asj/sjae251

BibTeX
@article{Kyriazidis2025,
  author = {Kyriazidis, Ioannis and Berner, Juan Enrique and Waked, Karl and Hamdi, Moustapha},
  title = {3D Breast Scanning in Plastic Surgery Utilizing Free iPhone LiDAR Application: Evaluation, Potential, and Limitations},
  journal = {Aesthetic Surgery Journal},
  year = {2025},
  doi = {10.1093/asj/sjae251}
}
Kostenlos starten →