EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

An Onset Detection Method for Slowly Activated Muscle Based on Marginal Spectrum Entropy

Xiaolei Huang, Jinzhuang Xiao, Qing Chang, Bin Fang

Sensors · 2025

DOI: 10.3390/s25102963 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Sensors, 2025. Verfasst von Xiaolei Huang und 3 weiteren Autor:innen. Beteiligte Einrichtung: College of Electrical Engineering, Hebei University of Architecture, Zhangjiakou 075000, China. Hauptthemen laut MEDLINE: Electromyography, Muscle, Skeletal. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 34 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Hebei University of Architecture.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Muscle activity is composed of fast and slow activations. The detection of the onset time of the electromyogram signal, which is slowly activated, is difficult. This paper proposes a detection method based on marginal spectral entropy (MSE). The surface electromyography (sEMG) signal of the soleus during normal walking was collected by a wireless electromyography acquisition system. The proposed MSE-based detection method is based on the Hilbert–Huang transform (HHT) combined with information entropy. By comparing the changes in MSE before and after muscle activation to plot a trend line, the point of fastest change on the trend line was defined as the onset time of muscle activation. This method was compared with the amplitude threshold method and the Teager–Kaiser energy (TKE) operator method. The results show that the onset time of muscle activation detected by this method is 0.14 s earlier than the amplitude threshold method and 0.16 s earlier than the TKE operator method. The detection results were significantly different (p < 0.05), indicating that this method has higher detection accuracy for the onset time of the sEMG signal, which is slowly activated.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

ElectromyographyMuscle, SkeletalHumansEntropyAlgorithmsSignal Processing, Computer-AssistedWalkingAdultMaleWireless Technology

Stichwörter der Autor:innen

Hilbert–Huang transform (HHT)marginal spectrum entropy (MSE)muscle activationslow activation

Autor:innen und Institutionen

  • College of Electrical Engineering, Hebei University of Architecture, Zhangjiakou 075000, China.
  • College of Eletronic and Information Engineering, Hebei University, Baoding 071000, China.

Förderung

  • Hebei University of Architecture

Zitieren

APA

Huang, X., Xiao, J., Chang, Q., & Fang, B. (2025). An Onset Detection Method for Slowly Activated Muscle Based on Marginal Spectrum Entropy. Sensors. https://doi.org/10.3390/s25102963

Vancouver

Huang X, Xiao J, Chang Q, Fang B. An Onset Detection Method for Slowly Activated Muscle Based on Marginal Spectrum Entropy. Sensors. 2025. doi:10.3390/s25102963

BibTeX
@article{Huang2025,
  author = {Huang, Xiaolei and Xiao, Jinzhuang and Chang, Qing and Fang, Bin},
  title = {An Onset Detection Method for Slowly Activated Muscle Based on Marginal Spectrum Entropy},
  journal = {Sensors},
  year = {2025},
  doi = {10.3390/s25102963}
}
Kostenlos starten →