EMG-based prediction of step direction for a better control of lower limb wearable devices

Eugenio Anselmino, Alberto Mazzoni, Silvestro Micera

Computer Methods and Programs in Biomedicine · 2024

DOI: 10.1016/j.cmpb.2024.108305 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Computer Methods and Programs in Biomedicine, 2024. Verfasst von Eugenio Anselmino und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Excellence in Robotics and AI, Scuola Superiore Sant'Anna, The BioRobotics Institute, Pisa, Italy. Electronic address: eugenio.anselmin…. Hauptthemen laut MEDLINE: Electromyography, Wearable Electronic Devices, Lower Extremity, Walking. Die Arbeit wurde bisher 9-mal zitiert (Crossref) und nennt 35 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND AND OBJECTIVES: Lower-limb wearable devices can significantly improve the quality of life of subjects suffering from debilitating conditions, such as amputations, neurodegenerative disorders, and stroke-related impairments. Current control approaches, limited to forward walking, fall short of replicating the complexity of human locomotion in complex environments, such as uneven terrains or crowded places. Here we propose a high-level controller based on two Support Vector Machines exploiting four surface electromyography (EMG) signals of the thigh muscles to detect the onset (Toe-off intention decoder) and the direction (Directional EMG decoder) of the upcoming step. METHODS AND MATERIALS: We validated a preliminary version of the approach by acquiring EMG signals from ten healthy subjects, performing steps in four directions (forward, backward, right, and left), in three different settings (ground-level walking, stairs, and ramps), and in both steady-state and static conditions. Both the Toe-off intention and Directional EMG decoders have been tested with a 5-fold cross-validation repeated five times, using linear and radial-basis-function kernels, and by changing the classification output timing, from 200 ms before to 50 ms after the toe-off. RESULTS: The Toe-off intention decoder reached a median accuracy of 83.34 % (interquartile range (IQR): 6.48) and specificity of 92.72 % (IQR: 3.62) in its radial-basis-function version, while the Directional EMG decoder's median accuracy ranged between 73.92 % (IQR: 5.8), 200 ms before the toe-off, to 92.91 % (IQR: 4.11), 50 ms after the toe-off, with the radial-basis-function kernel implementation. For both the Toe-off intention and Directional EMG decoders the radial-basis-function version achieved better performances than the linear one (Wilcoxon signed rank test, p < 0.05). CONCLUSIONS AND SIGNIFICANCE: The combination of the two decoders proved to be a promising solution to detect the step initiation and classify its direction, paving the way for wearable devices with a broader range of movements and more degrees of freedom, ultimately promoting usability in uncontrolled settings and better reactions to external perturbations. Additionally, the encumbrance of the setup is limited to the thigh of the leg of interest, which simplifies the implementation in compact devices, concurrently limiting the sensors worn by the subject.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

ElectromyographyWearable Electronic DevicesLower ExtremityWalkingSupport Vector MachineHumansAdultMaleFemaleAlgorithmsSignal Processing, Computer-AssistedMuscle, SkeletalYoung Adult

Stichwörter der Autor:innen

EMGGaitIntention decodingMachine learningWearable devices

Autor:innen und Institutionen

  • Department of Excellence in Robotics and AI, Scuola Superiore Sant'Anna, The BioRobotics Institute, Pisa, Italy. Electronic address: eugenio.anselmino@santannapisa.it.
  • Department of Excellence in Robotics and AI, Scuola Superiore Sant'Anna, The BioRobotics Institute, Pisa, Italy.
  • Department of Excellence in Robotics and AI, Scuola Superiore Sant'Anna, The BioRobotics Institute, Pisa, Italy; Bertarelli Foundation Chair in Translational Neuroengineering, EPFL, Genève, Switzerland.

Zitieren

APA

Anselmino, E., Mazzoni, A., & Micera, S. (2024). EMG-based prediction of step direction for a better control of lower limb wearable devices. Computer Methods and Programs in Biomedicine. https://doi.org/10.1016/j.cmpb.2024.108305

Vancouver

Anselmino E, Mazzoni A, Micera S. EMG-based prediction of step direction for a better control of lower limb wearable devices. Computer Methods and Programs in Biomedicine. 2024. doi:10.1016/j.cmpb.2024.108305

BibTeX
@article{Anselmino2024,
  author = {Anselmino, Eugenio and Mazzoni, Alberto and Micera, Silvestro},
  title = {EMG-based prediction of step direction for a better control of lower limb wearable devices},
  journal = {Computer Methods and Programs in Biomedicine},
  year = {2024},
  doi = {10.1016/j.cmpb.2024.108305}
}
Kostenlos starten →