A Transfer Learning Approach for Toe Walking Recognition Using Surface Electromyography on Leg Muscles
Sensors · 2025
DOI: 10.3390/s25051305 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, 2025. Verfasst von Andrea Manni und 4 weiteren Autor:innen. Beteiligte Einrichtung: National Research Council of Italy, Institute for Microelectronics and Microsystems, 73100 Lecce, Italy. Hauptthemen laut MEDLINE: Electromyography, Walking, Muscle, Skeletal, Leg. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 48 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Recovery and Resilience346 Plan (NRRP)-PE8-Mission 4, C2, Intervention 1.3, Next Generation EU, National Recovery and Resilience Plan (NRRP)-PE8-Mission 4, C2, Intervention 1.3.
Abstract (Originalsprache)
Gait is a complex motor process that involves the coordination and synchronization of various body parts through continuous interaction with the environment. Monitoring gait is crucial for the early detection of abnormalities, such as toe walking, which is characterized by limited or absent heel contact with the floor during walking. Persistent toe walking can cause severe foot, ankle, and musculature conditions; poor balance; increased risk of falling or tripping; and can affect overall quality of life, making it difficult, for example, to participate in sports or social activities. This study proposes a new approach to detect toe walking using surface Electromyography (sEMG) on lower limbs. sEMG sensors, by measuring the electrical activity of muscles, can see signals before the movement corresponding to muscle activation, contributing to an early detection of a possible problem. The sEMG signal presents significant complexity due to its noisy nature and the challenge of extracting meaningful features for classification. To address this issue and enhance the model’s robustness across different devices and configurations, a Transfer Learning (TL) approach is introduced. This method leverages pre-trained models to effectively handle the variability of sEMG data and improve classification accuracy. In particular, Continuous Wavelet Transform (CWT) is applied to sEMG-filtered signals (with time windows of 1 s) to convert them into 2D images (scalograms). Preliminary tests were performed on a public dataset using some of the most well-known pre-trained architectures, obtaining an accuracy of about 95% on InceptionResNetV2.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- National Research Council of Italy, Institute for Microelectronics and Microsystems, 73100 Lecce, Italy.
ORCID-Profile: Andrea Manni, Gabriele Rescio, Anna Maria Carluccio, Andrea Caroppo, Alessandro Leone
Förderung
- National Recovery and Resilience346 Plan (NRRP)-PE8-Mission 4, C2, Intervention 1.3
- Next Generation EU
- National Recovery and Resilience Plan (NRRP)-PE8-Mission 4, C2, Intervention 1.3
Zitieren
APA
Manni, A., Rescio, G., Carluccio, A. M., Caroppo, A., & Leone, A. (2025). A Transfer Learning Approach for Toe Walking Recognition Using Surface Electromyography on Leg Muscles. Sensors. https://doi.org/10.3390/s25051305
Vancouver
Manni A, Rescio G, Carluccio AM, Caroppo A, Leone A. A Transfer Learning Approach for Toe Walking Recognition Using Surface Electromyography on Leg Muscles. Sensors. 2025. doi:10.3390/s25051305
BibTeX
@article{Manni2025,
author = {Manni, Andrea and Rescio, Gabriele and Carluccio, Anna Maria and Caroppo, Andrea and Leone, Alessandro},
title = {A Transfer Learning Approach for Toe Walking Recognition Using Surface Electromyography on Leg Muscles},
journal = {Sensors},
year = {2025},
doi = {10.3390/s25051305}
}
EUVIMED