The Effects of Decreasing Foot Strike Angle on Lower Extremity Shock Attenuation Measured with Wearable Sensors
Sensors · 2025
DOI: 10.3390/s25092656 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, 2025. Verfasst von Lucas Sarantos und 4 weiteren Autor:innen. Beteiligte Einrichtung: Military Performance Division, U.S. Army Research Institute of Environmental Medicine, 10 General Greene Ave., Natick, MA 01760, USA. Hauptthemen laut MEDLINE: Wearable Electronic Devices, Gait, Lower Extremity, Foot. Die Arbeit nennt 35 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: U.S. Military Operational Medical Research Program, United States Army Medical Research and Development Command, Military Operational Medical Research Program.
Abstract (Originalsprache)
Shock attenuation may be a clinically feasible method to assess changes in lower extremity joint loading induced by gait modifications, such as decreasing foot strike angle (forefoot striking). The purpose of this study was to identify changes in lower extremity shock attenuation between habitual and forefoot strike gait conditions. Eighteen participants ran on a treadmill with their habitual gait and an instructed forefoot strike gait. Shock attenuation was measured with inertial measurement units as the ratio of proximal to distal peak resultant/vertical accelerations, with three sensor combinations: ankle to below/above knee (BK/A; AK/A) and AK/BK. Three participants were excluded who were habitual forefoot strikers or failed to decrease their foot strike angle by at least 5° in the forefoot strike condition. The results showed significantly greater resultant shock attenuation in the forefoot strike compared to the habitual condition for BK/A (mean Δ = 0.13, p = 0.004) and AK/A (mean Δ = 0.23, p = 0.007). No significant differences were found for AK/BK or vertical shock attenuation. These results suggest that shock attenuation may not reflect joint-specific loading changes that have been shown for forefoot striking (i.e., increased ankle/shank and decreased knee moments). However, it may capture changes in overall lower extremity loading (i.e., decreased vertical ground reaction forces).
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Military Performance Division, U.S. Army Research Institute of Environmental Medicine, 10 General Greene Ave., Natick, MA 01760, USA.
- Oak Ridge Institute for Science and Education, 100 Orau Way, Oak Ridge, TN 37830, USA.
ORCID-Profile: Cole A Dempsey, Caleb D Johnson
Förderung
- U.S. Military Operational Medical Research Program
- United States Army Medical Research and Development Command, Military Operational Medical Research Program
Zitieren
APA
Sarantos, L., Zeppetelli, D. J., Dempsey, C. A., Nagai, T., & Johnson, C. D. (2025). The Effects of Decreasing Foot Strike Angle on Lower Extremity Shock Attenuation Measured with Wearable Sensors. Sensors. https://doi.org/10.3390/s25092656
Vancouver
Sarantos L, Zeppetelli DJ, Dempsey CA, Nagai T, Johnson CD. The Effects of Decreasing Foot Strike Angle on Lower Extremity Shock Attenuation Measured with Wearable Sensors. Sensors. 2025. doi:10.3390/s25092656
BibTeX
@article{Sarantos2025,
author = {Sarantos, Lucas and Zeppetelli, David J and Dempsey, Cole A and Nagai, Takashi and Johnson, Caleb D},
title = {The Effects of Decreasing Foot Strike Angle on Lower Extremity Shock Attenuation Measured with Wearable Sensors},
journal = {Sensors},
year = {2025},
doi = {10.3390/s25092656}
}
EUVIMED