The FeetMe® Insoles System: Repeatability, Standard Error of Measure, and Responsiveness
Sensors · 2024
DOI: 10.3390/s24186043 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, 2024. Verfasst von Nathan Martin und 2 weiteren Autor:innen. Beteiligte Einrichtung: Pôle Parasport-ISPC Synergies, CHU Raymond Poincaré, APHP, 92380 Garches, France. Hauptthemen laut MEDLINE: Walking, Gait. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 61 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Background
Three-dimensional motion analysis using optoelectronic cameras and force platforms is typically used to quantify gait disorders. However, these systems have various limitations, particularly when assessing patients in an ecological environment. To address these limitations, several wearable devices have been developed. However, few studies have reported metrological information regarding their repeatability and sensitivity to change.
Methods
A healthy adult performed 6 min walking tests with FeetMe® system insoles under different walking conditions overground and on a treadmill. The standard error of measurement (SEM), the minimum detectable differences (MDDs), and the effect size (ES) were calculated for spatio-temporal parameters, and the ground reaction force was calculated from the 16,000 steps recorded.
Results
SEM values were below 3.9% for the ground reaction force and below 6.8% for spatio-temporal parameters. ES values were predominantly high, with 72.9% of cases between overground and treadmill conditions with induced asymmetry, and 64.5% of cases between treadmill conditions with and without induced asymmetry exhibiting an ES greater than 1.2. The minimum detectable differences ranged from 4.5% to 10.7% for ground reaction forces and 2.1% to 18.9% for spatio-temporal parameters.
Conclusion
Our study demonstrated that the FeetMe® system is a reliable solution. The sensitivity to change showed that these instrumented insoles can effectively reflect patient asymmetry and progress.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Pôle Parasport-ISPC Synergies, CHU Raymond Poincaré, APHP, 92380 Garches, France.
- Service de Médecine Physique et Réadapatation Locomotrice et Respiratoire, CHU Nantes, Nantes Université, 44093 Nantes, France.
- Movement-Interactions-Performance (MIP), EA 4334, CHU Nantes, Nantes Université, 44000 Nantes, France.
- U1179 Endicap, UVSQ, 78000 Versailles, France.
ORCID-Profile: Nathan Martin, Fabien Leboeuf
Zitieren
APA
Martin, N., Leboeuf, F., & Pradon, D. (2024). The FeetMe® Insoles System: Repeatability, Standard Error of Measure, and Responsiveness. Sensors. https://doi.org/10.3390/s24186043
Vancouver
Martin N, Leboeuf F, Pradon D. The FeetMe® Insoles System: Repeatability, Standard Error of Measure, and Responsiveness. Sensors. 2024. doi:10.3390/s24186043
BibTeX
@article{Martin2024,
author = {Martin, Nathan and Leboeuf, Fabien and Pradon, Didier},
title = {The FeetMe® Insoles System: Repeatability, Standard Error of Measure, and Responsiveness},
journal = {Sensors},
year = {2024},
doi = {10.3390/s24186043}
}