EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Automatic Identification of Lower-Limb Neuromuscular Activation Patterns During Gait Using a Textile Wearable Multisensor System

Federica Amitrano iD, Armando Coccia iD, Federico Colelli Riano iD, Gaetano Pagano iD, Arcangelo Biancardi, Ernesto Losavio iD, Giovanni D'Addio

Sensors · 2026

DOI: 10.3390/s26030997 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Sensors, 2026. Verfasst von Federica Amitrano und 6 weiteren Autor:innen. Beteiligte Einrichtung: Movement Analysis and Robotics Laboratory (MARLab), Istituti Clinici Scientifici Maugeri IRCCS, Telese Terme Institute, 82037 Benevento, Italy. Hauptthemen laut MEDLINE: Wearable Electronic Devices, Gait, Textiles, Lower Extremity. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 34 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Italian Minister of Economic Development, APTIS – Advanced Personalised Three-dimensional printed Sensorised orthosis project.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Wearable sensing technologies are increasingly used to assess neuromuscular function during daily-life activities. This study presents and evaluates a multisensor wearable system integrating a textile-based surface Electromyography (sEMG) sleeve and a pressure-sensing insole for monitoring Tibialis Anterior (TA) and Gastrocnemius Lateralis (GL) activation during gait. Eleven healthy adults performed overground walking trials while synchronised sEMG and plantar pressure signals were collected and processed using a dedicated algorithm for detecting activation intervals across gait cycles. All participants completed the walking protocol without discomfort, and the system provided stable recordings suitable for further analysis. The detected activation patterns showed one to four bursts per gait cycle, with consistent TA activity in terminal swing and GL activity in mid- to terminal stance. Additional short bursts were observed in early stance, pre-swing, and mid-stance depending on the pattern. The area under the sEMG envelope and the temporal features of each burst exhibited both inter- and intra-subject variability, consistent with known physiological modulation of gait-related muscle activity. The results demonstrate the feasibility of the proposed multisensor system for characterising muscle activation during walking. Its comfort, signal quality, and ease of integration encourage further applications in clinical gait assessment and remote monitoring. Future work will focus on system optimisation, simplified donning procedures, and validation in larger cohorts and populations with gait impairments.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Wearable Electronic DevicesGaitTextilesLower ExtremityBiosensing TechniquesHumansElectromyographyFemaleAdultMuscle, SkeletalMaleWalkingAlgorithms

Stichwörter der Autor:innen

e-textilegait analysismuscle activation patternsneuromotor rehabilitationplantar pressure sensorssurface electromyography (sEMG)textile-based electrodewearable health monitoringwearable sensors

Autor:innen und Institutionen

  • Movement Analysis and Robotics Laboratory (MARLab), Istituti Clinici Scientifici Maugeri IRCCS, Telese Terme Institute, 82037 Benevento, Italy.
  • Movement Analysis and Robotics Laboratory (MARLab), Istituti Clinici Scientifici Maugeri IRCCS, Bari Institute, 70124 Bari, Italy.
  • Neurology Unit, Istituti Clinici Scientifici Maugeri IRCCS, Bari Institute, 70124 Bari, Italy.

ORCID-Profile: Federica Amitrano, Armando Coccia, Federico Colelli Riano, Gaetano Pagano, Ernesto Losavio

Förderung

  • Italian Minister of Economic Development
  • APTIS – Advanced Personalised Three-dimensional printed Sensorised orthosis project

Zitieren

APA

Amitrano, F., Coccia, A., Colelli Riano, F., Pagano, G., Biancardi, A., Losavio, E., & D'Addio, G. (2026). Automatic Identification of Lower-Limb Neuromuscular Activation Patterns During Gait Using a Textile Wearable Multisensor System. Sensors. https://doi.org/10.3390/s26030997

Vancouver

Amitrano F, Coccia A, Colelli Riano F, Pagano G, Biancardi A, Losavio E, et al. Automatic Identification of Lower-Limb Neuromuscular Activation Patterns During Gait Using a Textile Wearable Multisensor System. Sensors. 2026. doi:10.3390/s26030997

BibTeX
@article{Amitrano2026,
  author = {Amitrano, Federica and Coccia, Armando and Colelli Riano, Federico and Pagano, Gaetano and Biancardi, Arcangelo and Losavio, Ernesto and D'Addio, Giovanni},
  title = {Automatic Identification of Lower-Limb Neuromuscular Activation Patterns During Gait Using a Textile Wearable Multisensor System},
  journal = {Sensors},
  year = {2026},
  doi = {10.3390/s26030997}
}
Kostenlos starten →