EUVIMEDEUVIMED entdecken
Crossref

Real-world application of a smartphone-based visual acuity test (WHOeyes) with automatic distance calibration

Yi Wu iD, Stuart Keel, Vera Lúcia Alves Carneiro, Shiran Zhang, Wei Wang iD, Chi Liu, Xuanzhang Tang, Xiaotong Han iD, Mingguang He iD

British Journal of Ophthalmology · 2024-11 · 108 (11) · 1613-1620

DOI: 10.1136/bjo-2023-324913 ↗

Kurz gefasst

Fachartikel in der Zeitschrift British Journal of Ophthalmology, online erschienen am 21.03.2024. Verfasst von Yi Wu und 8 weiteren Autor:innen. Beteiligte Einrichtung: State Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat-Sen University, Guangdong Provincial Key Laboratory of Ophthalmology and …. Hauptthemen laut MEDLINE: Visual Acuity, Smartphone, Vision Tests. Die Arbeit wurde bisher 14-mal zitiert (Crossref) und nennt 29 Literaturangaben. Gefördert von: World Health Organization, National Natural Science Foundation of China, Global STEM Professorship Scheme.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

To develop and assess the usability of a smartphone-based visual acuity (VA) test with an automatic distance calibration (ADC) function, the iOS version of WHOeyes.

Methods

The WHOeyes was an upgraded version with a distinct feature of ADC of an existing validated VA testing app called V@home. Three groups of Chinese participants with different ages (≤20, 20–40, >40 years) were recruited for distance and near VA testing using both an Early Treatment Diabetic Retinopathy Study (ETDRS) chart and the WHOeyes. The ADC function would determine the testing distance. Infrared rangefinder was used to determine the testing distance for the ETDRS, and actual testing distance for the WHOeyes. A questionnaire-based interview was administered to assess the satisfaction.

Results

The actual testing distance determined by the WHOeyes ADC showed an overall good agreement with the desired testing distance in all three age groups (p>0.50). Regarding the distance and near VA testing, the accuracy of WHOeyes was equivalent to ETDRS. The mean difference between the WHOeyes and ETDRS ranged from −0.084 to 0.012 logMAR, and the quadratic weighted kappa (QWK) values were >0.75 across all groups. The test–retest reliability of WHOeyes was high for both near and distance VA, with a mean difference ranging from −0.040 to 0.004 logMAR and QWK all >0.85. The questionnaire revealed an excellent user experience and acceptance of WHOeyes.

Conclusions

WHOeyes could provide accurate measurement of the testing distance as well as the distance and near VA when compared to the gold standard ETDRS chart.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Visual AcuitySmartphoneVision TestsHumansFemaleMaleAdultYoung AdultMiddle AgedCalibrationSurveys and QuestionnairesReproducibility of ResultsAgedMobile Applications

Stichwörter der Autor:innen

Low vision aidPublic healthSurveys and QuestionnairesVision

Autor:innen und Institutionen

  • State Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat-Sen University, Guangdong Provincial Key Laboratory of Ophthalmology and Visual Science, Guangdong Provincial Clinical Research Center for Ocul…
  • Department of Noncommunicable Diseases, Vision and eye care programme, World Health Organisation, Geneva, Switzerland.
  • Faculty of Data Science, City University of Macau, Macao SAR, China.
  • School of Optometry, The Hong Kong Polytechnic University, Kowloon, Hong Kong SAR, China.
  • Research Centre for SHARP Vision, The Hong Kong Polytechnic University, Kowloon, Hong Kong SAR, China.

ORCID-Profile: Yi Wu, Wei Wang, Xiaotong Han, Mingguang He

Förderung

  • World Health Organization
  • National Natural Science Foundation of China
  • Global STEM Professorship Scheme

Zitieren

APA

Wu, Y., Keel, S., Carneiro, V. L. A., Zhang, S., Wang, W., Liu, C., Tang, X., Han, X., & He, M. (2024). Real-world application of a smartphone-based visual acuity test (WHOeyes) with automatic distance calibration. British Journal of Ophthalmology, 108(11), 1613-1620. https://doi.org/10.1136/bjo-2023-324913

Vancouver

Wu Y, Keel S, Carneiro VLA, Zhang S, Wang W, Liu C, et al. Real-world application of a smartphone-based visual acuity test (WHOeyes) with automatic distance calibration. British Journal of Ophthalmology. 2024;108(11):1613-1620. doi:10.1136/bjo-2023-324913

BibTeX
@article{Wu2024,
  author = {Wu, Yi and Keel, Stuart and Carneiro, Vera Lúcia Alves and Zhang, Shiran and Wang, Wei and Liu, Chi and Tang, Xuanzhang and Han, Xiaotong and He, Mingguang},
  title = {Real-world application of a smartphone-based visual acuity test (WHOeyes) with automatic distance calibration},
  journal = {British Journal of Ophthalmology},
  year = {2024},
  volume = {108},
  number = {11},
  pages = {1613--1620},
  doi = {10.1136/bjo-2023-324913}
}