EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

AI‐Powered Smartphone Application for Measuring Hallux Valgus Angle From Radiographs Displayed on a Monitor

Ryutaro Takeda iD, Sanehiro Ando, Toshiko Iidaka iD, Kenta Makabe iD, Taro Kasai iD, Yasunori Omata iD, Noriko Yoshimura iD, Sakae Tanaka iD, Takumi Matsumoto iD

Journal of Foot and Ankle Research · 2025-09 · 18 (3)

DOI: 10.1002/jfa2.70081 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Foot and Ankle Research, online erschienen am 04.09.2025. Verfasst von Ryutaro Takeda und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopaedic Surgery, Faculty of Medicine, The University of Tokyo, Tokyo, Japan. Hauptthemen laut MEDLINE: Hallux Valgus, Smartphone, Mobile Applications, Radiography. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 12 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Japan Society for the Promotion of Science.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

We developed a smartphone application capable of automatically measuring the hallux valgus angle (HVA) and various intermetatarsal angles by capturing radiographic images displayed on a monitor. This study aimed to evaluate the accuracy of these measurements using the application.

Methods

Three users—a board‐certified orthopedic surgeon, a resident, and a nonhealthcare professional (Users 1, 2, and 3)—independently used the application to measure angles on 92 radiographs from 92 consecutive patients. Mean absolute errors (MAEs) between the application‐based measurements and the median of manual measurements performed by three experienced foot and ankle surgeons using a DICOM viewer were calculated for each user. To evaluate whether the measurement errors were acceptably small, one‐sided t‐tests were conducted to determine whether the MAEs were significantly less than 3°. Differences in MAEs among the three users were also assessed using analysis of variance.

Results

The MAEs of HVA by the three users were 1.1°, 1.3°, and 1.4°, respectively, all significantly below the 3° threshold (95% CI upper limit; 1.2°, 1.5°, and 1.5°). Comparable accuracy was observed for intermetatarsal angles, which have slightly greater variability for more lateral metatarsals. All measurements met the accuracy criterion of < 3°, except for the intermetatarsal angles between the first and fifth metatarsals measured by the nonhealthcare user. No significant difference in MAE was found among users for HVA ( p = 0.13), whereas significant differences were noted for some intermetatarsal angles.

Conclusions

The developed smartphone application accurately measured the HVA and various intermetatarsal angles, with performance comparable to that of experienced foot and ankle surgeons. Importantly, sufficient accuracy was achieved even when used by individuals without clinical training. The application may be useful as a practical tool in clinical and research settings.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Hallux ValgusSmartphoneMobile ApplicationsRadiographyHumansFemaleMaleMiddle AgedAdultAgedReproducibility of ResultsMetatarsal Bones

Stichwörter der Autor:innen

artificial intelligenceautomatic measurementhallux valgus angleintermetatarsal angleneural networksmartphone

Autor:innen und Institutionen

  • Department of Orthopaedic Surgery, Faculty of Medicine, The University of Tokyo, Tokyo, Japan.
  • Department of Preventive Medicine for Locomotive Organ Disorders, 22nd Century Medical and Research Center, Faculty of Medicine, The University of Tokyo, Tokyo, Japan.

ORCID-Profile: Ryutaro Takeda, Toshiko Iidaka, Kenta Makabe, Taro Kasai, Yasunori Omata, Noriko Yoshimura, Sakae Tanaka, Takumi Matsumoto

Förderung

  • Japan Society for the Promotion of Science

Zitieren

APA

Takeda, R., Ando, S., Iidaka, T., Makabe, K., Kasai, T., Omata, Y., Yoshimura, N., Tanaka, S., & Matsumoto, T. (2025). AI‐Powered Smartphone Application for Measuring Hallux Valgus Angle From Radiographs Displayed on a Monitor. Journal of Foot and Ankle Research, 18(3). https://doi.org/10.1002/jfa2.70081

Vancouver

Takeda R, Ando S, Iidaka T, Makabe K, Kasai T, Omata Y, et al. AI‐Powered Smartphone Application for Measuring Hallux Valgus Angle From Radiographs Displayed on a Monitor. Journal of Foot and Ankle Research. 2025;18(3). doi:10.1002/jfa2.70081

BibTeX
@article{Takeda2025,
  author = {Takeda, Ryutaro and Ando, Sanehiro and Iidaka, Toshiko and Makabe, Kenta and Kasai, Taro and Omata, Yasunori and Yoshimura, Noriko and Tanaka, Sakae and Matsumoto, Takumi},
  title = {AI‐Powered Smartphone Application for Measuring Hallux Valgus Angle From Radiographs Displayed on a Monitor},
  journal = {Journal of Foot and Ankle Research},
  year = {2025},
  volume = {18},
  number = {3},
  doi = {10.1002/jfa2.70081}
}
Kostenlos starten →