EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Indirect Thermographic Measurement of the Temperature of a Transistor Die during Pulse Operation

Arkadiusz Hulewicz iD, Krzysztof Dziarski iD, Łukasz Drużyński

Sensors · 06.10.2024 · 24 (19) · 6452

DOI: 10.3390/s24196452 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Sensors, online erschienen am 06.10.2024. Verfasst von Arkadiusz Hulewicz und 2 weiteren Autor:innen. Beteiligte Einrichtung: Institute of Electrical Engineering and Electronics, Poznan University of Technology, Piotrowo 3A, 60-965 Poznan, Poland. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 42 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Poznań University of Technology, Ministry of Science and Higher Education.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This paper presents aspects related to the indirect thermographic measurement of a C2M0280120D transistor in pulse mode. The tested transistor was made on the basis of silicon carbide and is commonly used in many applications. During the research, the pulse frequency was varied from 1 kHz to 800 kHz. The transistor case temperature was measured using a Flir E50 thermographic camera and a Pt1000 sensor. The transistor die temperature was determined based on the voltage drop on the body diode and the known characteristics between the voltage drop on the diode and the temperature of the die. The research was carried out in accordance with the presented measuring standards and maintaining the described conditions. The differences between the transistor case temperature and the transistor die temperature were also determined based on simulation work performed in Solidworks 2020 SP05. For this purpose, a three-dimensional model of the C2M0280120D transistor was created and the materials used in this model were selected; the methodology for selecting the model parameters is discussed. The largest recorded difference between the case temperature and the junction temperature was 27.3 °C. The use of a thermographic camera allows the transistor’s temperature to be determined without the risk of electric shock. As a result, it will be possible to control the C2M0280120D transistor in such a way so as not to damage it and to optimally select its operating point.

Schlagwörter

Stichwörter der Autor:innen

C2M0280120Dsolidworksswitchingthermal modellingthermographytransistor

Autor:innen und Institutionen

  • Institute of Electrical Engineering and Electronics, Poznan University of Technology, Piotrowo 3A, 60-965 Poznan, Poland.
  • Institute of Electric Power Engineering, Poznan University of Technology, Piotrowo 3A, 60-965 Poznan, Poland.

ORCID-Profile: Arkadiusz Hulewicz, Krzysztof Dziarski

Förderung

  • Poznań University of Technology
  • Ministry of Science and Higher Education

Zitieren

APA

Hulewicz, A., Dziarski, K., & Drużyński, Ł. (2024). Indirect Thermographic Measurement of the Temperature of a Transistor Die during Pulse Operation. Sensors, 24(19), 6452. https://doi.org/10.3390/s24196452

Vancouver

Hulewicz A, Dziarski K, Drużyński Ł. Indirect Thermographic Measurement of the Temperature of a Transistor Die during Pulse Operation. Sensors. 2024;24(19):6452. doi:10.3390/s24196452

BibTeX
@article{Hulewicz2024,
  author = {Hulewicz, Arkadiusz and Dziarski, Krzysztof and Drużyński, Łukasz},
  title = {Indirect Thermographic Measurement of the Temperature of a Transistor Die during Pulse Operation},
  journal = {Sensors},
  year = {2024},
  volume = {24},
  number = {19},
  pages = {6452},
  doi = {10.3390/s24196452}
}