EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Ultrasound Image Temperature Monitoring Based on a Temporal-Informed Neural Network

Yuxiang Han, Yongxing Du, Limin He, Xianwei Meng, Minchao Li, Fujun Cao iD

Sensors · 2024

DOI: 10.3390/s24154934 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Sensors, 2024. Verfasst von Yuxiang Han und 5 weiteren Autor:innen. Beteiligte Einrichtung: School of Digital and Intelligence Industry, Inner Mongolia University of Science & Technology, Baotou 014000, China. Hauptthemen laut MEDLINE: Neural Networks, Computer, Ultrasonography, Phantoms, Imaging, Temperature. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 35 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Natural Science Foundation of China, Inner Mongolia Natural Science Foundation of China, Inner Mongolia Autonomous Region Science and Technology Major Project.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Real-time and accurate temperature monitoring during microwave hyperthermia (MH) remains a critical challenge for ensuring treatment efficacy and patient safety. This study presents a novel approach to simulate real MH and precisely determine the temperature of the target region within biological tissues using a temporal-informed neural network. We conducted MH experiments on 30 sets of phantoms and 10 sets of ex vivo pork tissues. We proposed a novel perspective: the evolving tissue responses to continuous electromagnetic radiation stimulation are a joint evolution in temporal and spatial dimensions. Our model leverages TimesNet to extract periodic features and Cloblock to capture global information relevance in two-dimensional periodic vectors from ultrasound images. By assimilating more ultrasound temporal data, our model improves temperature-estimation accuracy. In the temperature range 25–65 °C, our neural network achieved temperature-estimation root mean squared errors of approximately 0.886 °C and 0.419 °C for fresh ex vivo pork tissue and phantoms, respectively. The proposed temporal-informed neural network has a modest parameter count, rendering it suitable for deployment on ultrasound mobile devices. Furthermore, it achieves temperature accuracy close to that prescribed by clinical standards, making it effective for non-destructive temperature monitoring during MH of biological tissues.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Neural Networks, ComputerUltrasonographyPhantoms, ImagingTemperatureAnimalsSwineMicrowavesHyperthermia, InducedHumans

Stichwörter der Autor:innen

microwave hyperthermianeural networksnon-invasive temperature monitoringultrasound

Autor:innen und Institutionen

  • School of Digital and Intelligence Industry, Inner Mongolia University of Science & Technology, Baotou 014000, China.
  • School of Science, Inner Mongolia University of Science & Technology, Baotou 014000, China.
  • Laboratory of Controllable Preparation and Application of Nanomaterials, Technical Institute of Physics and Chemistry, Chinese Academy of Sciences, Beijing 100190, China.

ORCID-Profile: Fujun Cao

Förderung

  • National Natural Science Foundation of China
  • Inner Mongolia Natural Science Foundation of China
  • Inner Mongolia Autonomous Region Science and Technology Major Project

Zitieren

APA

Han, Y., Du, Y., He, L., Meng, X., Li, M., & Cao, F. (2024). Ultrasound Image Temperature Monitoring Based on a Temporal-Informed Neural Network. Sensors. https://doi.org/10.3390/s24154934

Vancouver

Han Y, Du Y, He L, Meng X, Li M, Cao F. Ultrasound Image Temperature Monitoring Based on a Temporal-Informed Neural Network. Sensors. 2024. doi:10.3390/s24154934

BibTeX
@article{Han2024,
  author = {Han, Yuxiang and Du, Yongxing and He, Limin and Meng, Xianwei and Li, Minchao and Cao, Fujun},
  title = {Ultrasound Image Temperature Monitoring Based on a Temporal-Informed Neural Network},
  journal = {Sensors},
  year = {2024},
  doi = {10.3390/s24154934}
}
Kostenlos starten →