EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

A 3 MHz Low-Error Adaptive Howland Current Source for High-Frequency Bioimpedance Applications

Ifeabunike I Nwokoye iD, Iasonas F Triantis iD

Sensors · 04.07.2024 · 24 (13) · 4357

DOI: 10.3390/s24134357 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Sensors, online erschienen am 04.07.2024. Verfasst von Ifeabunike I Nwokoye und 1 weiteren Autor:innen. Beteiligte Einrichtung: Research Centre for Biomedical Engineering, City, University of London, London EC1V 0HB, UK. Hauptthemen laut MEDLINE: Electric Impedance. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 38 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Bioimpedance is a diagnostic sensing method used in medical applications, ranging from body composition assessment to detecting skin cancer. Commonly, discrete-component (and at times integrated) circuit variants of the Howland Current Source (HCS) topology are employed for injection of an AC current. Ideally, its amplitude should remain within 1% of its nominal value across a frequency range, and that nominal value should be programmable. However, the method’s applicability and accuracy are hindered due to the current amplitude diminishing at frequencies above 100 kHz, with very few designs accomplishing 1 MHz, and only at a single nominal amplitude. This paper presents the design and implementation of an adaptive current source for bioimpedance applications employing automatic gain control (AGC). The “Adaptive Howland Current Source” (AHCS) was experimentally tested, and the results indicate that the design can achieve less than 1% amplitude error for both 1 mA and 100 µA currents for bandwidths up to 3 MHz. Simulations also indicate that the system can be designed to achieve up to 19% noise reduction relative to the most common HCS design. AHCS addresses the need for high bandwidth AC current sources in bioimpedance spectroscopy, offering automatic output current compensation without constant recalibration. The novel structure of AHCS proves crucial in applications requiring higher β-dispersion frequencies exceeding 1 MHz, where greater penetration depths and better cell status assessment can be achieved, e.g., in the detection of skin or breast cancer.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Electric ImpedanceHumansDielectric SpectroscopyBody Composition

Stichwörter der Autor:innen

AC current sourceHowland current sourcebioelectrical impedancebioimpedanceelectrical impedanceimpedance spectroscopy

Autor:innen und Institutionen

  • Research Centre for Biomedical Engineering, City, University of London, London EC1V 0HB, UK.

ORCID-Profile: Ifeabunike I Nwokoye, Iasonas F Triantis

Zitieren

APA

Nwokoye, I. I., & Triantis, I. F. (2024). A 3 MHz Low-Error Adaptive Howland Current Source for High-Frequency Bioimpedance Applications. Sensors, 24(13), 4357. https://doi.org/10.3390/s24134357

Vancouver

Nwokoye II, Triantis IF. A 3 MHz Low-Error Adaptive Howland Current Source for High-Frequency Bioimpedance Applications. Sensors. 2024;24(13):4357. doi:10.3390/s24134357

BibTeX
@article{Nwokoye2024,
  author = {Nwokoye, Ifeabunike I and Triantis, Iasonas F},
  title = {A 3 MHz Low-Error Adaptive Howland Current Source for High-Frequency Bioimpedance Applications},
  journal = {Sensors},
  year = {2024},
  volume = {24},
  number = {13},
  pages = {4357},
  doi = {10.3390/s24134357}
}