EUVIMEDEUVIMED entdecken
Multizentrische StudieBeobachtungsstudieQuerschnittstudieOpen Access · CC BY-NC 4.0

Portable Electrical Impedance Prescreening for Breast tissue suspicious for malignancy: Model Optimization and Clinical Performance of the Julieta Device in a Multicenter Cross-Sectional Study in Colombia

Maria Andrea Negret iD, Valentina González iD, David Grajales iD, Maria Alejandra Velez iD, Maria Alejandra Yepez iD, Valentina Agudelo iD, Sergio Lopez iD, Clara Piedrahita

Technology in Cancer Research & Treatment · 2026

DOI: 10.1177/15330338261422902 ↗

Kurz gefasst

Multizentrische Studie in der Zeitschrift Technology in Cancer Research & Treatment, 2026. Verfasst von Maria Andrea Negret und 7 weiteren Autor:innen. Beteiligte Einrichtung: Internal Medicine Physician, Pontifical Xavierian University, Bogotá, Colombia. Hauptthemen laut MEDLINE: Breast Neoplasms, Electric Impedance, Early Detection of Cancer, Dielectric Spectroscopy. Die Arbeit nennt 29 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

Breast cancer remains a leading cause of cancer mortality despite being potentially curable when detected early, particularly in low- and middle-income countries where access to screening is limited. This is largely driven by operational gaps, including limited access to screening and delays in diagnosis and treatment. JULIETA is a portable bioimpedance spectroscopy device designed to identify electrical tissue patterns associated with potentially malignant findings and to prioritize women for further diagnostic evaluation. This study assessed the performance of a hierarchical algorithm integrated into JULIETA to distinguish findings without malignant potential (BI-RADS 1-2) from those with malignant potential (BI-RADS ≥3), using mammography as the reference standard.

Methods

A cross-sectional observational study with prospective data collection was conducted between May and July 2024 in four Colombian cities. Adult women undergoing screening or follow-up mammography were evaluated with JULIETA prior to imaging. Impedance-derived features, breast density estimates, and individual risk scores were used to retrain a hierarchical classifier combining Random Forest and SVM-RBF models, using an 80/20 stratified split and cross-validation.

Results

A total of 1350 women were recruited (mean age 56.5 ± 8.0 years); 67% were BI-RADS 1-2 and 21% BI-RADS 4. After data cleaning, 673 breasts (469 women) were included. The model achieved 73% sensitivity, 76% specificity, 65.5% positive predictive value, and 82.1% negative predictive value.

Conclusion

JULIETA is a feasible, safe, and reproducible noninvasive bioimpedance pre-screening tool that may enable scalable triage and support earlier detection and improved equity when integrated into public health pathways.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Breast NeoplasmsElectric ImpedanceEarly Detection of CancerDielectric SpectroscopyHumansFemaleCross-Sectional StudiesMiddle AgedColombiaAgedAdultMammographyProspective Studies

Stichwörter der Autor:innen

breast cancerbreast neoplasmscancer screeningearly cancer detectionelectrical impedance

Autor:innen und Institutionen

  • Internal Medicine Physician, Pontifical Xavierian University, Bogotá, Colombia.
  • Clinical Specialist, SalvaHealth, Medellín, Bogotá, Colombia.
  • Biomedical Engineering, Los Andes University, Bogotá, Colombia.
  • Research and Development Engineer, SalvaHealth, Medellín, Bogotá, Colombia.
  • Biomedical Engineering and PhD in Biomedical Engineering, Polytechnic Montreal Louise-Lalonde-Lamarre Library, Montreal, Canada.
  • Head of Artificial Intelligence, SalvaHealth, Medellín, Colombia.

ORCID-Profile: Maria Andrea Negret, Valentina González, David Grajales, Maria Alejandra Velez, Maria Alejandra Yepez, Valentina Agudelo, Sergio Lopez

Zitieren

APA

Negret, M. A., González, V., Grajales, D., Velez, M. A., Yepez, M. A., Agudelo, V., Lopez, S., & Piedrahita, C. (2026). Portable Electrical Impedance Prescreening for Breast tissue suspicious for malignancy: Model Optimization and Clinical Performance of the Julieta Device in a Multicenter Cross-Sectional Study in Colombia. Technology in Cancer Research & Treatment. https://doi.org/10.1177/15330338261422902

Vancouver

Negret MA, González V, Grajales D, Velez MA, Yepez MA, Agudelo V, et al. Portable Electrical Impedance Prescreening for Breast tissue suspicious for malignancy: Model Optimization and Clinical Performance of the Julieta Device in a Multicenter Cross-Sectional Study in Colombia. Technology in Cancer Research & Treatment. 2026. doi:10.1177/15330338261422902

BibTeX
@article{Negret2026,
  author = {Negret, Maria Andrea and González, Valentina and Grajales, David and Velez, Maria Alejandra and Yepez, Maria Alejandra and Agudelo, Valentina and Lopez, Sergio and Piedrahita, Clara},
  title = {Portable Electrical Impedance Prescreening for Breast tissue suspicious for malignancy: Model Optimization and Clinical Performance of the Julieta Device in a Multicenter Cross-Sectional Study in Colombia},
  journal = {Technology in Cancer Research & Treatment},
  year = {2026},
  doi = {10.1177/15330338261422902}
}
Kostenlos starten →